Kinetic behavior of urea is different from that of other water-soluble compounds: The case of the guanidino compounds

112Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background. Although patients with renal failure retain a large variety of solutes, urea is virtually the only currently applied marker for adequacy of dialysis. Only a limited number of other compounds have up until now been investigated regarding their intradialytic kinetics. Scant data suggest that large solutes show a kinetic behavior that is different from urea. The question investigated in this study was whether other small water-soluble solutes, such as some guanidino compounds, show a kinetic behavior comparable or dissimilar to that of urea. Methods. This study included 7 stable conventional hemodialysis patients without native kidney function undergoing low flux polysulphone dialysis (F8 and F10HPS). Blood samples were collected from the inlet and outlet bloodlines immediately before the dialysis session, after 5, 15, 30, 120 minutes, and immediately after discontinuation of the session. Plasma concentrations of urea, creatinine (CTN), creatine (CT), guanidinosuccinic acid (GSA), guanidinoacetic acid (GAA), guanidine (G), and methylguanidine (MG) were used to calculate corresponding dialyzer clearances. A two-pool kinetic model was fitted to the measured plasma concentration profiles, resulting in the calculation of the perfused volume (V1), the total distribution volume (Vtot), and the intercompartmental clearance (K12); solute generation and overall ultrafiltration were determined independently. Results. No significant differences were observed between V1 and K12 for urea (6.4 ± 3.3 L and 822 ± 345mL/min, respectively) and for the guanidino compounds. However, with respect to V tot, GSA was distributed in a smaller volume (30.6 ± 4.2 L) compared to urea (42.7 ± 6.0L) (P < 0.001), while CTN, CT, GAA, G, and MG showed significantly higher volumes (54.0 ± 5.9 L, 98.0 ± 52.3 L, 123.8 ± 66.9 L, 89.7 ± 21.4 L, 102.6 ± 33.9 L, respectively; P = 0.004, = 0.033, = 0.003, < 0.001, = 0.001, respectively). These differences resulted in divergent effective solute removal: 67% (urea), 58% (CTN), 42% (CT), 76% (GSA), 37% (GAA), 43% (G), and 42% (MG). Conclusion. The kinetics of the guanidino compounds under study are different from that of urea; hence, urea kinetics are not representative for the removal of other uremic solutes, even if they are small and water-soluble like urea. © 2005 by the International Society of Nephrology.

Cite

CITATION STYLE

APA

Eloot, S., Torremans, A., De Smet, R., Marescau, B., De Wachter, D., De Deyn, P. P., … Vanholder, R. (2005). Kinetic behavior of urea is different from that of other water-soluble compounds: The case of the guanidino compounds. Kidney International, 67(4), 1566–1575. https://doi.org/10.1111/j.1523-1755.2005.00238.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free