This procedure guideline describes the procedures for dynamic renal scintigraphy with (99m)Tc-MAG3, (123)I-hippuran and (99m)Tc-DTPA. Common clinical applications as well as a detailed description of the procedure are given. It also includes explanations and hints concerning the analysis, evaluation, interpretation, and presentation of the findings.

Author-supplied keywords

  • DTPA
  • Dynamic renography
  • Hippuran
  • MAG3
  • Procedure guideline