Results of the first air ion spectrometer calibration and intercomparison workshop

Asmi E, Sipilä M, Manninen H, Vanhanen J, Lehtipalo K, Gagné S, Neitola K, Mirme A, Mirme S, Tamm E, Uin J, Komsaare K, Attoui M, Kulmala M ...see all

Atmospheric Chemistry and Physics Discussions, vol. 8, issue 5 (2008) pp. 17257-17295

  • 26

    Readers

    Mendeley users who have this article in their library.
  • 54

    Citations

    Citations of this article.
Sign in to save reference

Abstract

The Air Ion Spectrometer (AIS) measures mobility and size distributions of atmospheric ions. The Neutral cluster and Air Ion Spectrometer (NAIS) can additionally measure neutral particles. The number of the (N)AIS instruments in the world is only 11. Nevertheless, they are already widely used in atmospheric ion studies, particularly related to the initial steps of new particle formation. There is no standard method applicable for calibrating the ion spectrometers in the sub-3 nm ion range. However, recent development of high resolution DMAs has enabled the size separation of small ions with good mobility resolution. For the first time, the ion spectrometers were intercompared and calibrated in a workshop, held in JanuaryFebruary 2008 in Helsinki, Finland. The overall goal was to experimentally determine the (N)AIS transfer functions. Monomobile mobility standards, 241-Am charger ions and silver particles were generated and used as calibration aerosols. High resolution DMAs were used to size-separate the smaller (110 nm) ions, while at bigger diameters (440 nm) the size was selected with a HAUKE-type DMA. Negative ion mobilities were detected by (N)AISs with slightly better accuracy than positive, nonetheless, both were somewhat overestimated. A linear fit of slope of one to the whole dataset of mobilities suggested that (N)AISs measured the negative mobilities 1.360.16 times larger compared with the reference instruments. Similarly, positive mobilities were measured 1.390.15 times larger compared with the reference instruments. The completely monomobile mobility standards were measured with the best accuracy. The (N)AIS concentrations were compared with an aerosol electrometer (AE) and a condensation particle counter (CPC). At sizes below 1.5 nm (positive) and 3 nm (negative) the ion spectrometers detected higher concentrations while at bigger sizes they showed similar concentrations as the reference instruments. The total particle concentrations measured by the NAISs were within 50% of the reference CPC concentration at 440 nm sizes. The lowest cut-off size of the NAIS in neutral particle measurements was determined to be between 1.5 and 3 nm, depending on the measurement conditions and the polarity.

Get free article suggestions today

Mendeley saves you time finding and organizing research

Sign up here
Already have an account ?Sign in

Find this document

Get full text

Authors

  • E. Asmi

  • M. Sipilä

  • H. E. Manninen

  • J. Vanhanen

  • K. Lehtipalo

  • S. Gagné

Cite this document

Choose a citation style from the tabs below

Save time finding and organizing research with Mendeley

Sign up for free