Utilization guidelines for reducing radiation exposure in the evaluation of aneurysmal subarachnoid hemorrhage: A practice quality improvement project

20Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.
Get full text

Abstract

OBJECTIVE. The purpose of this study was to reduce the cumulative radiation exposure from CT of patients with aneurysmal subarachnoid hemorrhage. MATERIALS AND METHODS. Baseline data on 30 patients with aneurysmal sub-arachnoid hemorrhage were collected retrospectively for all CT examinations of the head performed throughout the hospital course. Radiation exposure estimates were obtained by recording dose-length products for each examination. As a departmental practice quality improvement project, an imaging protocol was implemented that included utilization guidelines to reduce radiation exposure in CTA and CT perfusion examinations performed to detect vasospasm in patients with aneurysmal subarachnoid hemorrhage. Ten months after implementation of this protocol, data on 30 additional patients were analyzed. Means, medians, and SD estimates were compared for cumulative radiation exposure and absolute numbers of each examination. RESULTS. Sixty patients were included in the study: 30 patients at baseline and 30 patients after implementation of the quality improvement plan. These patients underwent 435 CT examinations: 248 examinations at baseline and 187 examinations with the new protocol. With the new algorithm, the mean number of CT examinations per patient was 5.8 compared with 7.8 at baseline, representing a decrease of 25.6%. The number of CT perfusion examinations per patient decreased 32.1%. Overall, there was a 12.1% decrease in cumulative radiation exposure (p > 0.05). CONCLUSION. With the structured imaging algorithm, the cumulative radiation exposure and number of CT examinations of the head decreased among patients with aneurysmal subarachnoid hemorrhage because utilization guidelines defined the appropriate imaging time points for detection of vasospasm. Application of these methods to other patient populations with high use of CT may reduce cumulative radiation exposure while the clinical benefits of imaging are maintained. © American Roentgen Ray Society.

Cite

CITATION STYLE

APA

Loftus, M. L., Minkowitz, S., Tsiouris, A. J., Min, R. J., & Sanelli, P. C. (2010). Utilization guidelines for reducing radiation exposure in the evaluation of aneurysmal subarachnoid hemorrhage: A practice quality improvement project. American Journal of Roentgenology, 195(1), 176–180. https://doi.org/10.2214/AJR.09.3786

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free