Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging

34Citations
Citations of this article
54Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose Clinical PET/MR acquisition protocols entail the use of MR contrast agents (MRCA) that could potentially affect PET quantification following MR-based attenuation correction (AC). We assessed the effect of oral and intravenous (IV) MRCA on PET quantification in PET/MR imaging. Methods We employed two MRCA: Lumirem® (oral) and Gadovist® (IV). First, we determined their reference PET attenuation values using a PET transmission scan (ECATEXACT HR+, Siemens) and a CT scan (PET/CT Biograph 16 HI-REZ, Siemens). Second, we evaluated the attenuation of PET signals in the presence of MRCA. Phantoms were filled with clinically relevant concentrations of MRCA in a background of water and 18F-fluoride, and imaged using a PET/CT scanner (Biograph 16 HI-REZ, Siemens) and a PET/ MR scanner (Biograph mMR, Siemens). Third, we investigated the effect of clinically relevant volumes of MRCA on MR-based AC using human pilot data: a patient study employing Gadovist® (IV) and a volunteer study employing two different oral MRCA (Lumirem® and pineapple juice). MR-based attenuationmapswere calculated following Dixonbased fat-water segmentation and an external atlas-based and pattern recognition (AT&PR) algorithm. Results IV and oral MRCA in clinically relevant concentrations were found to have PET attenuation values similar to those of water. The phantom experiments showed that under clinical conditions IV and oral MRCA did not yield additional attenuation of PET emission signals. Patient scans showed that PET attenuation maps are not biased after the administration of IV MRCA but may be biased, however, after ingestion of iron oxide-based oral MRCA when segmentation-based AC algorithms are used. Alternative AC algorithms, such as AT&PR, or alternative oral contrast agents, such as pineapple juice, can yield unbiased attenuation maps. Conclusion In clinical PET/MR scenarios MRCA are not expected to lead to markedly increased attenuation of the PET emission signals. MR-based attenuation maps may be biased by oral iron oxide-based MRCA unless advanced AC algorithms are used. © Springer-Verlag 2012.

Cite

CITATION STYLE

APA

Lois, C., Bezrukov, I., Schmidt, H., Schwenzer, N., Werner, M. K., Kupferschläger, J., & Beyer, T. (2012). Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging. European Journal of Nuclear Medicine and Molecular Imaging, 39(11), 1756–1766. https://doi.org/10.1007/s00259-012-2190-0

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free