Intracoronary ultrasound assessment of morphological and functional abnormalities associated with cardiac allograft vasculopathy

24Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Background: The diffuse nature of cardiac allograft vasculopathy makes early detection of the disease by traditional noninvasive methods or coronary angiography difficult. The aim of this study was to determine if there is a relation between abnormalities in vessel wall morphology, as assessed by intracoronary ultrasound, and a decreased vasodilatory response to the endothelium-dependent vasodilator papaverine hydrochloride and if cardiac allograft vasculopathy detected by coronary angiography is associated with specific intracoronary ultrasound findings. Methods and Results: Twenty- three heart transplant recipients underwent 25 intracoronary ultrasound studies and 24 studies of coronary vasomotor tone 10 days to 8.3 years after surgery using a 20-mHz intracoronary ultrasound catheter. The studies were divided in two groups according to the presence (n = 7, group 1) or absence (n = 18, group 2) of angiographically evident cardiac allograft vasculopathy. Qualitative assessment of vessel wall morphology and quantitative analysis of the vasodilator response to the injection of papaverine hydrochloride into the coronary artery distal to the imaging site were performed off-line, and results for the two study groups were compared. A significantly higher percentage of patients with than without angiographic evidence of cardiac allograft vasculopathy had a three-interface vessel wall morphology by intracoronary ultrasound (100% versus 11%, P

Author supplied keywords

References Powered by Scopus

Paradoxical Vasoconstriction Induced by Acetylcholine in Atherosclerotic Coronary Arteries

2133Citations
N/AReaders
Get full text

Flow-induced release of endothelium-derived relaxing factor

1388Citations
N/AReaders
Get full text

Crucial role of endothelium in the vasodilator response to increased flow in vivo

814Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Coronary angioplasty, atherectomy and bypass surgery in cardiac transplant recipients

190Citations
N/AReaders
Get full text

Development of transplantation vasculopathy and progression of donor- transmitted atherosclerosis: Comparison by serial intravascular ultrasound imaging

106Citations
N/AReaders
Get full text

Coronary flow velocity pattern and coronary flow reserve by contrast-enhanced transthoracic echocardiography predict long-term outcome in heart transplantation

90Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Heroux, A. L., Silverman, P., Costanzo, M. R., O’Sullivan, E. J., Johnson, M. R., Liao, Y., … Johnson, S. A. (1994). Intracoronary ultrasound assessment of morphological and functional abnormalities associated with cardiac allograft vasculopathy. Circulation, 89(1), 272–277. https://doi.org/10.1161/01.CIR.89.1.272