Target localization and toxicity in dose-escalated prostate radiotherapy with image-guided approach using daily planar kilovoltage imaging

5Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Dose escalation with intensity-modulated radiation therapy (IMRT) for carcinoma of the prostate has augmented the need for accurate prostate localization prior to dose delivery. Daily planar kilovoltage (kV) imaging is a low-dose image-guidance technique that is prevalent among radiation oncologists. However, clinical outcomes evaluating the benefit of daily kV imaging are lacking. The purpose of this study was to report our clinical experience, including prostate motion and gastrointestinal (GI) and genitourinary (GU) toxicities, using this modality. A retrospective analysis of 100 patients treated consecutively between December 2005 and March 2008 with definitive external beam IMRT for T1c-T4 disease were included in this analysis. Prescription doses ranged from 74-78 Gy (median, 76) in 2 Gy fractions and were delivered following daily prostate localization using on-board kV imaging (OBI) to localize gold seed fiducial markers within the prostate. Acute and late toxicities were graded as per the NCI CTCAEv3.0. The median follow-up was 22 months. The magnitude and direction of prostate displacement and daily shifts in three axes are reported. Of note, 9.1% and 12.9% of prostate displacements were ≥ 5 mm in the anterior-posterior and superior-inferior directions, respectively. Acute grade 2 GI and GU events occurred in 11% and 39% of patients, respectively, however no grade 3 or higher acute GI or GU events were observed. Regarding late toxicity, 2% and 17% of patients developed grade 2 toxicities, and similarly no grade 3 or higher events had occurred by last follow-up. Thus, kV imaging detected a substantial amount of inter-fractional displacement and may help reduce toxicity profiles, especially high grade events, by improving the accuracy of dose delivery. ©Adenine Press (2011).

References Powered by Scopus

Toxicity criteria of the Radiation Therapy Oncology Group (RTOG) and the European organization for research and treatment of cancer (EORTC)

4240Citations
N/AReaders
Get full text

CTCAE v3.0: Development of a comprehensive grading system for the adverse effects of cancer treatment

2364Citations
N/AReaders
Get full text

Defining biochemical failure following radiotherapy with or without hormonal therapy in men with clinically localized prostate cancer: Recommendations of the RTOG-ASTRO Phoenix Consensus Conference

2351Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Rectal toxicity after proton therapy for prostate cancer: An analysis of outcomes of prospective studies conducted at the University of Florida Proton Therapy Institute

41Citations
N/AReaders
Get full text

Improvement of patient localization repeatability using a light-section based optical surface guidance system in a pre-positioning procedure

2Citations
N/AReaders
Get full text

Development of dedicated phantom for end-to-end testing of multiple image-guidance configurations incorporating light-section-based surface guidance system

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Nath, S. K., Sandhu, A. P., Sethi, R. A., Jensen, L. G., Rosario, M. D., Kane, C. J., … Mundt, A. J. (2011). Target localization and toxicity in dose-escalated prostate radiotherapy with image-guided approach using daily planar kilovoltage imaging. Technology in Cancer Research and Treatment, 10(1), 31–37. https://doi.org/10.7785/tcrt.2012.500177

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

47%

Professor / Associate Prof. 5

33%

Researcher 3

20%

Readers' Discipline

Tooltip

Medicine and Dentistry 5

50%

Nursing and Health Professions 3

30%

Computer Science 1

10%

Neuroscience 1

10%

Save time finding and organizing research with Mendeley

Sign up for free