First Clinical Results of the Merit WRAPSODY™ Cell-Impermeable Endoprosthesis for Treatment of Access Circuit Stenosis in Haemodialysis Patients

8Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

PURPOSE: This prospective, observational first in human study evaluated the safety and effectiveness of WRAPSODYTM Cell-impermeable Endoprosthesis (Merit Medical Systems, Inc.) in the treatment of arteriovenous fistula and arteriovenous graft access circuit stenosis. MATERIALS AND METHODS: Investigators conducted a prospective analysis of 46 patients with access circuit stenosis from three centres. Treatment sites included the peripheral outflow veins (e.g. cephalic arch, basilic vein swing point; 16 fistula and 10 graft patients); the graft-vein anastomosis (9 patients); and the central veins (up to, but not including the SVC; 11 patients). Primary outcome measures included 30-day freedom from access circuit-related safety events and 30-day target lesion primary patency. Secondary outcome measures included procedural success; device- and procedure-related adverse events; target lesion primary patency; access circuit primary patency; and secondary patency. In-person follow-up was scheduled at 1, 3, 6, and 12 months. An independent data monitoring/clinical event committee adjudicated all reinterventions and device/procedure-relatedness for adverse events. RESULTS: All initial procedures were successful. All but one patient was free from safety events through the first 30 days (97.8% (45/46)). This event was not device-related. Over the remainder of the study, one adverse event was adjudicated as possibly device-related. Six- and 12-month target lesion primary patency rates were 97.7% (42/43) and 84.6.% (33/39), respectively. Six- and 12-month access circuit primary patency rates were 84.4% (38/45) and 65.9% (29/44), respectively. CONCLUSION: Results suggest that the study device is safe and effective for treatment of stenoses in the peripheral and central veins of arteriovenous access circuits. LEVEL OF EVIDENCE: Level 2b, cohort study.

Cited by Powered by Scopus

First Clinical Results of the Merit WRAPSODY™ Cell-Impermeable Endoprosthesis for Treatment of Access Circuit Stenosis in Haemodialysis Patients

4Citations
N/AReaders
Get full text

Hemodialysis Access Stent Graft Trials: Past, Present, and Future

2Citations
N/AReaders
Get full text

The impact of stent-graft sizing on venous stenosis re-intervention and arteriovenous graft patency: Free-floating stent outflow is associated with improved outcomes

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Gilbert, J., Rai, J., Kingsmore, D., Skousen, J., & Ptohis, N. (2021). First Clinical Results of the Merit WRAPSODYTM Cell-Impermeable Endoprosthesis for Treatment of Access Circuit Stenosis in Haemodialysis Patients. Cardiovascular and Interventional Radiology, 44(12), 1903–1913. https://doi.org/10.1007/s00270-021-02953-8

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

70%

Researcher 2

20%

Lecturer / Post doc 1

10%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

67%

Pharmacology, Toxicology and Pharmaceut... 1

11%

Nursing and Health Professions 1

11%

Earth and Planetary Sciences 1

11%

Article Metrics

Tooltip
Mentions
News Mentions: 12

Save time finding and organizing research with Mendeley

Sign up for free