An entrained-flow system has been designed and constructed to simulate in-flight mercury (Hg) capture by sorbent injection in ducts of coal-fired utility plants. The test conditions of 1.2-sec residence time, 140 °C gas temperature, 6.7 m/sec (22 ft/sec) gas velocity, and 0-0.24 g/m3 (0-15 lbs of sorbent per 1 million actual cubic feet of flue gas [lb/MMacf]) sorbent injection rates were chosen to simulate conditions in the ducts. Four kinds of sorbents were used in this study. Darco Hg-LH served as a bench-mark sorbent with which Hg control capability of other sorbents could be compared. Also, Darco-FGD was used as a representative raw activated carbon sorbent. Two different copper chloride-impregnated sorbents were developed in our laboratory and tested in the entrained-flow system to examine the possibility of using these sorbents at coal-fired power plants. The test results showed that one of the copper chloride sorbents has remarkable elemental mercury (Hgo) oxidation capability, and the other sorbent demonstrated a better performance in Hg removal than Darco Hg-LH. Copyright 2008 Air & Waste Management Association.
CITATION STYLE
Lee, S. S., Lee, J. Y., & Keener, T. C. (2008). Performance of copper chloride-impregnated sorbents on mercury vapor control in an entrained-flow reactor system. Journal of the Air and Waste Management Association, 58(11), 1458–1462. https://doi.org/10.3155/1047-3289.58.11.1458