Background: Methotrexate (MTX) may produce antiarthritic effects through polyglutamation to methotrexate polyglutamates (MTXPGs), a process that covalently attaches sequential γ-linked glutamic residues to MTX. We sought to develop an innovative HPLC method for the quantification of these metabolites in erythrocytes. Methods: Two alternative approaches were developed. In the first approach, MTXPGs from 50 μL of packed erythrocytes were converted to MTX in the presence of plasma γ-glutamyl hydrolase and mercaptoethanol at 37°C. In the second approach, MTXPG species (up to the hepta order of glutamation) from 100 μL packed erythrocytes were directly quantified in a single run. In both methods, the MTXPGs were extracted from the biological matrix by a simple perchloric acid deproteinization step with direct injection of the extract into the HPLC. The chromatography used a C 18 reversed-phase column, an ammonium acetate/acetonitrile buffer, and postcolumn photo-oxidation of MTXPGs to fluorescent analytes. Results: Intra- and interday imprecision (CVs) were <10% at low and high concentrations of analytes for both methods. The limit of quantification was 5 nmol/L. In 70 patients with rheumatoid arthritis receiving weekly low-dose MTX, the mean (SD) total MTXPG concentration measured after conversion of MTXPGs to MTX was similar to the total MTXPG concentration calculated from the sum of individual MTXPG species [117 (56) vs 120 (59) nmol/L; r = 0.97; slope = 1.0]. The triglutamate predominated over all other MTXPG species (36% of total), the pentaglutamate was the highest order of glutamation detected, and a stability study revealed no change in the polyglutamation pattern in erythrocytes 48 h after phlebotomy when the specimen was stored at 2-8°C. Conclusion: The proposed method for quantification of erythrocyte MTXPGs is rapid, sensitive, and accurate and can be applied to the routine monitoring of MTX therapy. © 2003 American Association for Clinical Chemistry.

Cite

CITATION STYLE

APA

Dervieux, T., Lein, D. O., Marcelletti, J., Pischel, K., Smith, K., Walsh, M., & Richerson, R. (2003). HPLC determination of erythrocyte methotrexate polyglutamates after low-dose methotrexate therapy in patients with rheumatoid arthritis. Clinical Chemistry, 49(10), 1632–1641. https://doi.org/10.1373/49.10.1632

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free