Empiricism in Microsampling: Utilizing a Novel Lateral Flow Device and Intrinsic Normalization to Provide Accurate and Precise Clinical Analysis from a Finger Stick

16Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Phlebotomy plays a key role in clinical laboratory medicine but poses certain challenges for the patient and the laboratory. Dried blood spots simplify collection and stabilize specimens effectively, but clinical reference intervals are based primarily on serum or plasma. We evaluated use of dried separated blood plasma specimens to simplify plasma sample collection via finger stick; however, this sampling technique posed substantial analytical challenges. We discuss herein our efforts to overcome these challenges and provide accurate and precise clinical measurements. Methods: Microsamples of whole blood were collected via finger stick using a collection device employing laminar-flow separation of cellular blood and plasma fractions with subsequent desiccation. Samples were analyzed on modern autoanalyzers with FDA-approved reagent and calibration systems, as well as commercially available reagents with laboratory-developed assay parameters. Measured analyte concentrations from extracted dried plasma samples were normalized to a coextracted endogenous analyte, chloride. Results: Chloride normalization reduced variability incurred through extraction and undefined plasma volume. Excellent correlation of normalized measurements from dried finger-stick samples (whole blood and plasma) versus matched venous samples facilitated developing mathematical transformations to provide concordance between specimen types. Independent end-to-end performance verification yielded mean biases <3% for the 5 analytes evaluated relative to venous drawn samples analyzed on FDA-approved measurement systems. Conclusion: Challenges inherent with this microsampling technique and alternate sample matrix were obviated through capabilities of modern autoanalyzers and implementation of chloride normalization. These results demonstrate that self-collected microsamples from a finger stick can give results concordant with those of venous samples.

Cite

CITATION STYLE

APA

Crawford, M. L., Collier, B. B., Bradley, M. N., Holland, P. L., Shuford, C. M., & Grant, R. P. (2020). Empiricism in Microsampling: Utilizing a Novel Lateral Flow Device and Intrinsic Normalization to Provide Accurate and Precise Clinical Analysis from a Finger Stick. Clinical Chemistry, 66(6), 821–831. https://doi.org/10.1093/clinchem/hvaa082

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free