Time-domain substructure transient vibration transfer path analysis based on time-varying frequency response functions under operational excitations

4Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The time-domain substructure inverse matrix method has become a popular method to detect and diagnose problems regarding vehicle noise, vibration, and harshness, especially for those impulse excitations caused by roads. However, owning to its reliance on frequency response functions (FRFs), the approach is effective only for time-invariable linear or weak nonlinear systems. This limitation prevents this method from being applied to a typical vehicle suspension substructure, which shows different nonlinear characteristics under different wheel transient loads. In this study, operational excitation was considered as a key factor and applied to calculate dynamic time-varying FRFs to perform accurate time-domain transient vibration transfer path analysis (TPA). The core idea of this novel method is to divide whole coupled substructural relationships into two parts: One involved time-invariable components; normal FRFs could be obtained through tests directly. The other involved numerical computations of the time-domain operational loads matrix and FRFs matrix in static conditions. This method focused on determining dynamic FRFs affected by operational loads, especially the severe transient ones; these loads are difficult to be considered in other classical TPA approaches, such as operational path analysis with exogenous inputs (OPAX) and operational transfer path analysis (OTPA). Experimental results showed that this new approach could overcome the limitations of the traditional time-domain substructure TPA in terms of its strict requirements within time-invariable systems. This is because in the new method, time-varying FRFs were calculated and used, which could make the FRFs at the system level directly adapt to time-varying systems from time to time. In summary, the modified method extends TPA objects studied in time-invariable systems to time-varying systems and, thus, makes a methodology and application innovation compared to traditional the time-domain substructure TPA.

Cite

CITATION STYLE

APA

He, R., & Zhou, H. (2019). Time-domain substructure transient vibration transfer path analysis based on time-varying frequency response functions under operational excitations. Shock and Vibration, 2019. https://doi.org/10.1155/2019/2030326

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free