The direct agglutination test (DAT) based on a freeze-dried antigen and the rK39 dipstick test were evaluated for the sero-diagnosis of visceral leishmaniasis (VL). The sensitivity and specificity of both tests were determined using sera from confirmed VL patients (n = 21), healthy controls (n = 19) and from patients with other confirmed infectious diseases (n = 42). The DA T had a sensitivity and a specificity of 100%. The rK39 had a sensitivity of 85.7% and a specificity of 82%. Both tests were also used to screen blood samples of confirmed VL patients (n = 15) and serum samples of VL suspecis (n = 61). The DAT found all blood samples of confirmed VL patients positive and tested 98.4% of the serum samples of the VL suspects positive. In contrast. rK39 detected in 9/15 blood samples (60%) antibodies against Leishmania chagasi and found 85.3% of the serum samples of the suspected patients positive. Although the rK39 dipstick is more rapid and user friendlier than the DAT, the latter has a superior sensitivity and specificity. Furthermore, the reagents used for DAT do not require cold storage, whereas the buffer of the rK39 must be stored at 4°C. Therefore, the DA T is the most suitable test for the sero-diagnosis of VL under field conditions.
CITATION STYLE
Schallig, H. D. F. H., Canto-Cavalheiro, M., & Da Silva, E. S. (2002). Evaluation of the direct agglutination test and the rK39 dipstick test for the sero-diagnosis of visceral leishmaniasis. Memorias Do Instituto Oswaldo Cruz. Fundacao Oswaldo Cruz. https://doi.org/10.1590/S0074-02762002000700015