Heuristic optimization of the scanning path of particle therapy beams

13Citations
Citations of this article
31Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Quasidiscrete scanning is a delivery strategy for proton and ion beam therapy in which the beam is turned off when a slice is finished and a new energy must be set but not during the scanning between consecutive spots. Different scanning paths lead to different dose distributions due to the contribution of the unintended transit dose between spots. In this work an algorithm to optimize the scanning path for quasidiscrete scanned beams is presented. The classical simulated annealing algorithm is used. It is a heuristic algorithm frequently used in combinatorial optimization problems, which allows us to obtain nearly optimal solutions in acceptable running times. A study focused on the best choice of operational parameters on which the algorithm performance depends is presented. The convergence properties of the algorithm have been further improved by using the next-neighbor algorithm to generate the starting paths. Scanning paths for two clinical treatments have been optimized. The optimized paths are found to be shorter than the back-and-forth, top-to-bottom (zigzag) paths generally provided by the treatment planning systems. The gamma method has been applied to quantify the improvement achieved on the dose distribution. Results show a reduction of the transit dose when the optimized paths are used. The benefit is clear especially when the fluence per spot is low, as in the case of repainting. The minimization of the transit dose can potentially allow the use of higher beam intensities, thus decreasing the treatment time. The algorithm implemented for this work can optimize efficiently the scanning path of quasidiscrete scanned particle beams. Optimized scanning paths decrease the transit dose and lead to better dose distributions. © 2009 American Association of Physicists in Medicine.

References Powered by Scopus

Optimization by simulated annealing

34748Citations
N/AReaders
Get full text

A technique for the quantitative evaluation of dose distributions

2395Citations
N/AReaders
Get full text

Magnetic scanning system for heavy ion therapy

691Citations
N/AReaders
Get full text

Cited by Powered by Scopus

A study on repainting strategies for treating moderately moving targets with proton pencil beam scanning at the new gantry 2 at PSI

154Citations
N/AReaders
Get full text

Review of technologies and procedures of clinical dosimetry for scanned ion beam radiotherapy

37Citations
N/AReaders
Get full text

First experimental results of motion mitigation by continuous line scanning of protons

27Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Pardo, J., Donetti, M., Bourhaleb, F., Ansarinejad, A., Attili, A., Cirio, R., … Sacchi, R. (2009). Heuristic optimization of the scanning path of particle therapy beams. Medical Physics, 36(6), 2043–2051. https://doi.org/10.1118/1.3121506

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 12

48%

Researcher 8

32%

Professor / Associate Prof. 5

20%

Readers' Discipline

Tooltip

Physics and Astronomy 16

67%

Medicine and Dentistry 4

17%

Computer Science 3

13%

Agricultural and Biological Sciences 1

4%

Save time finding and organizing research with Mendeley