Quantitative pulsatility measurements using 3D dynamic ultrasound localization microscopy

11Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

A rise in blood flow velocity variations (i.e. pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with large penetration depth and high spatiotemporal resolution. The development of dynamic ultrasound localization microscopy (DULM), based on ULM, has enabled pulsatility measurements in the rodent brain in 2D. However, 2D imaging accesses only one slice of the brain and measures only 2D-projected and hence biased velocities . Herein, we present 3D DULM: using a single ultrasound scanner at high frame rate (1000-2000 Hz), this method can produce dynamic maps of microbubbles flowing in the bloodstream and extract quantitative pulsatility measurements in the cat brain with craniotomy and in the mouse brain through the skull, showing a wide range of flow hemodynamics in both large and small vessels. We highlighted a decrease in pulsatility along the vascular tree in the cat brain, which could be mapped with ultrasound down to a few tens of micrometers for the first time. We also performed an intra-animal validation of the method by showing consistent measurements between the two sides of the Willis circle in the mouse brain. Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the brain, which could be linked to early signs of neurodegenerative diseases.

References Powered by Scopus

Multiscale vessel enhancement filtering

3575Citations
N/AReaders
Get full text

Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging

972Citations
N/AReaders
Get full text

Super-resolution Ultrasound Imaging

357Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Dynamic Ultrasound Localization Microscopy Without ECG-Gating

4Citations
N/AReaders
Get full text

3D ultrasound localization microscopy of the nonhuman primate brain

3Citations
N/AReaders
Get full text

A Tracking Prior to Localization Workflow for Ultrasound Localization Microscopy

2Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Bourquin, C., Porée, J., Rauby, B., Perrot, V., Ghigo, N., Belgharbi, H., … Provost, J. (2024). Quantitative pulsatility measurements using 3D dynamic ultrasound localization microscopy. Physics in Medicine and Biology, 69(4). https://doi.org/10.1088/1361-6560/ad1b68

Readers over time

‘23‘24‘25036912

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

67%

Researcher 3

33%

Readers' Discipline

Tooltip

Engineering 7

70%

Physics and Astronomy 2

20%

Neuroscience 1

10%

Save time finding and organizing research with Mendeley

Sign up for free
0