4D flow MR imaging of ophthalmic artery flow in patients with internal carotid artery stenosis

14Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

Abstract

Background and Purpose: To assess the clinical feasibility of time-resolved 3D phase contrast (4D Flow) MRI assessment of the ophthalmic artery (OphA) flow in patients with internal carotid artery stenosis (ICS). Materials and Methods: Twenty-one consecutive patients with unilateral ICS were recruited. 4D Flow MRI and acetazolamide-stress brain perfusion single photon emission computed tomography (SPECT) were per­formed. The flow direction on the affected-side OphA was categorized into native flow (anterograde or unclear) and non-native flow (retrograde flow) based on 4D Flow MRI. In the affected-side middle cerebral artery (MCA) territory, the ratio of rest cerebral blood flow to normal control (RCBFMCA) and cerebral vas­cular reserve (CVRMCA) were calculated from SPECT dataset. High-risk patients were defined based on the previous large cohort study (RCBFMCA < 80% and CVRMCA < 10%). Results: Eleven patients had native OphA flow (4 anterograde, 7 unclear) and the remaining 10 had non-native OphA flow. RCBFMCA and CVRMCA each were significantly lower in non-native flow group (84.9 ± 18.9% vs. 69.8 ± 7.3%, P < 0.05; 36.4 ± 20.6% vs. 17.0 ± 15.0%, P < 0.05). Four patients in the non-native flow group and none in the native flow group were confirmed as high-risk (Sensitivity/Specificity, 1.00/0.65). Conclusion: The 6 min standard 4D Flow MRI assessment of OphA in patients with ICS can predict intra­cranial hemodynamic impairment.

References Powered by Scopus

Collateral circulation

920Citations
N/AReaders
Get full text

4D flow MRI

670Citations
N/AReaders
Get full text

Complications of diagnostic cerebral angiography: Evaluation of 19 826 consecutive patients

524Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Abnormal flow dynamics result in low wall shear stress and high oscillatory shear index in abdominal aortic dilatation: Initial in vivo assessment with 4D-flow MRI

30Citations
N/AReaders
Get full text

4D flow MRI hemodynamic biomarkers for cerebrovascular diseases

25Citations
N/AReaders
Get full text

Blood flow analysis with computational fluid dynamics and 4D-flow MRI for vascular diseases

19Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Sekine, T., Takagi, R., Amano, Y., Murai, Y., Orita, E., Fukushima, Y., … Kumita, S. I. (2018). 4D flow MR imaging of ophthalmic artery flow in patients with internal carotid artery stenosis. Magnetic Resonance in Medical Sciences, 17(1), 13–20. https://doi.org/10.2463/mrms.mp.2016-0074

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

62%

Researcher 3

23%

Professor / Associate Prof. 1

8%

Lecturer / Post doc 1

8%

Readers' Discipline

Tooltip

Medicine and Dentistry 4

44%

Engineering 3

33%

Philosophy 1

11%

Neuroscience 1

11%

Save time finding and organizing research with Mendeley

Sign up for free