Comparative assessment on ramp and bias voltage variations of closed loop interferometric fiber optic gyroscope

3Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

Background/Objectives: The main objective of this paper is to perform a comparative discussion in gyro parameters for three cases: (i) V2π (vary) & Vπ/2 (constant), (ii) Vπ/2 (vary) and Vπp (constant) and (iii) both Vπp and Vπ/2 are varying simultaneously. Methods/Statistical Analysis: Fibre optic gyroscope has to be operated in closed-loop approach to achieve the inertial-grade-performance. The Closed-Loop Interferometric Fibre Optic Gyroscope (CLIFOG) system depends upon ramp voltage (Vπp of IOC) and square-wave biasing signal frequency (fbias). The digital-phase-ramp-function is used as feedback to system and makes gyro to null condition. The biasing signal voltage (Vπ/2) is 1/4th of ramp voltage (Vπp). If there are any variations in ramp and biasing signal voltages, then it introduces variations in gyro performance. Results: The ramp voltage (Vπp) and square wave biasing signal voltage (Vπ/2) is increased from 1% to 10%, decreased to 1% to 10% and performed the various tests for three cases. From results, it was noted that: (i) When V2π is varying and Vπ/2 is kept constant, the scale-factor change is increasing as the error in the signal voltage is also increases. (ii) When V2π is kept constant and Vπ/2 is varying, the change in scale-factor is very minute and maintains the scale-factor linearity. (iii) While varying both V2π and Vπ/2 voltages simultaneously, the device is not responding accordingly as the error is increasing and also scale-factor is out of range subsequently. The effects on the CLIFOG system are described with the derived values in terms of bias and scale-factor. The gyro performance is very sensitive with respect to Vπp variations and the percentage error is high in gyro output, but very less effect due to Vπ/2 variations when the ramp voltage (V2π) is constant. Conclusion/Application: The Closed Loop Interferometric Fiber Optic Gyroscope (CLIFOG) system requires a proper resetting of ramp voltage (V2π) in order to avoid the bias and scale factor instabilities.

Cite

CITATION STYLE

APA

Sireesha, T., & Sreenivasa Ravi, K. (2015). Comparative assessment on ramp and bias voltage variations of closed loop interferometric fiber optic gyroscope. Indian Journal of Science and Technology, 8(18). https://doi.org/10.17485/ijst/2015/v8i18/67723

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free