Accuracy of [18F]fluorodopa positron emission tomography for diagnosing and localizing focal congenital hyperinsulinism

122Citations
Citations of this article
33Readers
Mendeley users who have this article in their library.

Abstract

Objectives: Focal lesions in infants with congenital hyperinsulinism (HI) represent areas of adenomatosis that express a paternally derived ATP-sensitive potassium channel mutation due to embryonic loss of heterozygosity for the maternal 11p region. This study evaluated the accuracy of 18F-fluoro- L-dihydroxyphenylalanine ([18F]DOPA) positron emission tomography (PET) scans in diagnosing focal vs. diffuse disease and identifying the location of focal lesions. Design: A total of 50 infants with HI unresponsive to medical therapy were studied. Patients were injected iv with [18F]DOPA, and PET scans were obtained for 50-60 min. Images were coregistered with abdominal computed tomography scans. PET scan interpretations were compared with histological diagnoses. Results: The diagnosis of focal or diffuse HI was correct in 44 of the 50 cases (88%). [18F]DOPA PET identified focal areas of high uptake of radiopharmaceutical in 18 of 24 patients with focal disease. The locations of these lesions matched the areas of increased [ 18F]DOPA uptake on the PET scans in all of the cases. PET scan correctly located five lesions that could not be visualized at surgery. The positive predictive value of [18F]DOPA in diagnosing focal adenomatosis was 100%, and the negative predictive value was 81%. Conclusions: [18F]DOPA PET scans correctly diagnosed 75% of focal cases and were 100% accurate in identifying the location of the lesion. These results suggest that [18F]DOPA PET imaging provides a useful guide to surgical resection of focal adenomatosis and should be considered as a guide to surgery in all infants with congenital HI who have medically uncontrollable disease. Copyright © 2007 by The Endocrine Society.

Cite

CITATION STYLE

APA

Hardy, O. T., Hernandez-Pampaloni, M., Saffer, J. R., Scheuermann, J. S., Ernst, L. M., Freifelder, R., … Stanley, C. A. (2007). Accuracy of [18F]fluorodopa positron emission tomography for diagnosing and localizing focal congenital hyperinsulinism. Journal of Clinical Endocrinology and Metabolism, 92(12), 4706–4711. https://doi.org/10.1210/jc.2007-1637

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free