Comparison of iterative model reconstruction versus filtered back-projection in pediatric emergency head CT: Dose, image quality, and image-reconstruction times

21Citations
Citations of this article
84Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND AND PURPOSE: Noncontrast CT of the head is the initial imaging test for traumatic brain injury, stroke, or suspected nonaccidental trauma. Low-dose head CT protocols using filtered back-projection are susceptible to increased noise and decreased image quality. Iterative reconstruction noise suppression allows the use of lower-dose techniques with maintained image quality. We review our experience with children undergoing emergency head CT examinations reconstructed using knowledge-based iterative model reconstruction versus standard filtered back-projection, comparing reconstruction times, radiation dose, and objective and subjective image quality. MATERIALS AND METHODS: This was a retrospective study comparing 173 children scanned using standard age-based noncontrast head CT protocols reconstructed with filtered back-projection with 190 children scanned using low-dose protocols reconstructed with iterative model reconstruction. ROIs placed on the frontal white matter and thalamus yielded signal-to-noise and contrast-to-noise ratios. Volume CT dose index and study reconstruction times were recorded. Random subgroups of patients were selected for subjective image-quality review. RESULTS: The volume CT dose index was significantly reduced in studies reconstructed with iterative model reconstruction compared with filtered back-projection, (mean, 24.4±3.1 mGy versus 31.1±6.0 mGy, P < .001). Radiologists graded iterative model reconstruction images as superior to filtered back-projection images for gray-white matter differentiation and anatomic detail (P < .001). The average reconstruction time of the filtered back-projection studies was 101 seconds, and with iterative model reconstruction, it was 147 seconds (P < .001), without a practical effect on work flow. CONCLUSIONS: In children referred for emergency noncontrast head CT, optimized low-dose protocols with iterative model reconstruction allowed us to significantly reduce the relative dose, on average, 22% compared with filtered back-projection, with significantly improved objective and subjective image quality.

Cite

CITATION STYLE

APA

Southard, R. N., Bardo, D. M. E., Temkit, M. H., Thorkelson, M. A., Augustyn, R. A., & Martinot, C. A. (2019). Comparison of iterative model reconstruction versus filtered back-projection in pediatric emergency head CT: Dose, image quality, and image-reconstruction times. American Journal of Neuroradiology, 40(5), 866–871. https://doi.org/10.3174/ajnr.A6034

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free