Spinal manipulation characteristics: a scoping literature review of force-time characteristics

2Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Spinal manipulation (SM) is a recommended and effective treatment for musculoskeletal disorders. Biomechanical (kinetic) parameters (e.g. preload/peak force, rate of force application and thrust duration) can be measured during SM, quantifying the intervention. Understanding these force-time characteristics is the first step towards identifying possible active ingredient/s responsible for the clinical effectiveness of SM. Few studies have quantified SM force-time characteristics and with considerable heterogeneity evident, interpretation of findings is difficult. The aim of this study was to synthesise the literature describing force-time characteristics of manual SM. Methods: This scoping literature review is reported following the Preferred Reporting Items for Scoping Reviews (PRISMA-ScR) statement. Databases were searched from inception to October 2022: MEDLINE (Ovid), Embase, CINAHL, ICL, PEDro and Cochrane Library. The following search terms and their derivatives were adapted for each platform: spine, spinal, manipulation, mobilization or mobilisation, musculoskeletal, chiropractic, osteopathy, physiotherapy, naprapathy, force, motor skill, biomechanics, dosage, dose-response, education, performance, psychomotor, back, neck, spine, thoracic, lumbar, pelvic, cervical and sacral. Data were extracted and reported descriptively for the following domains: general study characteristics, number of and characteristics of individuals who delivered/received SM, region treated, equipment used and force-time characteristics of SM. Results: Of 7,607 records identified, 66 (0.9%) fulfilled the eligibility criteria and were included in the analysis. Of these, SM was delivered to the cervical spine in 12 (18.2%), the thoracic spine in 40 (60.6%) and the lumbopelvic spine in 19 (28.8%) studies. In 6 (9.1%) studies, the spinal region was not specified. For SM applied to all spinal regions, force-time characteristics were: preload force (range: 0-671N); peak force (17-1213N); rate of force application (202-8700N/s); time to peak thrust force (12-938ms); and thrust duration (36-2876ms). Conclusions: Considerable variability in the reported kinetic force-time characteristics of SM exists. Some of this variability is likely due to differences in SM delivery (e.g. different clinicians) and the measurement equipment used to quantify force-time characteristics. However, improved reporting in certain key areas could facilitate more sophisticated syntheses of force-time characteristics data in the future. Such syntheses could provide the foundation upon which dose-response estimates regarding the clinical effectiveness of SM are made.

Cite

CITATION STYLE

APA

Gorrell, L. M., Nyirö, L., Pasquier, M., Pagé, I., Heneghan, N. R., Schweinhardt, P., & Descarreaux, M. (2023). Spinal manipulation characteristics: a scoping literature review of force-time characteristics. Chiropractic and Manual Therapies, 31(1). https://doi.org/10.1186/s12998-023-00512-1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free