Cooling and Water Production in a Hybrid Desiccant M-Cycle Evaporative Cooling System with HDH Desalination: A Comparison of Operational Modes

3Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

Highlights: What are the main findings? A hybrid desiccant M-cycle cooling system with an HDH unit is proposed for simultaneous cooling and water production. Three typical operational modes are analysed and compared in terms of cooling and water production. What is the implication of the main finding? The recirculation mode exhibited a superior cooling performance than the other two modes. The water production rates and system COP were similar among the three modes. In this paper, the cooling and freshwater generation performance of a novel hybrid configuration of a solid desiccant-based M-cycle cooling system (SDM) combined with a humidification–dehumidification (HDH) desalination unit is analysed and compared in three operational modes: ventilation, recirculation, and half recirculation. The HDH unit in this system recycles the moist waste air sourced from the M-cycle cooler and rotary desiccant wheel of the SDM system to enhance water production. A mathematical model was established and solved using TRNSYS and EES software. The results of this study indicate that the recirculation mode exhibited superior cooling performance compared to the other two modes, producing up to 7.91 kW of cooling load and maintaining a supply air temperature below 20.85 °C and humidity of 12.72 g/kg under various ambient conditions. All the operational modes showed similar water production rates of around 52.74 kg/h, 52.43 kg/h, and 52.14 kg/h for the recirculation, half-recirculation and ventilation modes, respectively, across a range of operating temperatures. The recirculation mode also exhibited a higher COP compared to the other modes, as the environmental temperature and relative humidity were above 35 °C and 50%. However, it should be noted that the implementation of the recirculation mode resulted in a higher water consumption rate, with a maximum value of 5.52 kg/h when the inlet air reached 45 °C, which partially offset the benefits of this mode.

References Powered by Scopus

Recent progress in the use of renewable energy sources to power water desalination plants

540Citations
N/AReaders
Get full text

Thermodynamic analysis of humidification dehumidification desalination cycles

342Citations
N/AReaders
Get full text

Recent progress on desiccant materials for solid desiccant cooling systems

301Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Optimisation of cooling performance and water consumption of a solid desiccant-assisted indirect evaporative cooling system using response surface methodology

1Citations
N/AReaders
Get full text

Design of a Seawater Desalination System with Two-Stage Humidification and Dehumidification Desalination Driven by Wind and Solar Energy

1Citations
N/AReaders
Get full text

A review of co-generative and synergistic desalination & refrigeration systems for sustainable development applications

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lai, L., Wang, X., Kefayati, G., & Hu, E. (2023). Cooling and Water Production in a Hybrid Desiccant M-Cycle Evaporative Cooling System with HDH Desalination: A Comparison of Operational Modes. Processes, 11(2). https://doi.org/10.3390/pr11020611

Readers over time

‘23‘24‘25036912

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

50%

Professor / Associate Prof. 3

38%

Researcher 1

13%

Readers' Discipline

Tooltip

Engineering 7

64%

Energy 3

27%

Environmental Science 1

9%

Article Metrics

Tooltip
Mentions
Blog Mentions: 1
News Mentions: 1

Save time finding and organizing research with Mendeley

Sign up for free
0