Detectors assessment for stereotactic radiosurgery with cones

9Citations
Citations of this article
41Readers
Mendeley users who have this article in their library.

Abstract

The purpose of this work is to assess eight detectors performance for output factor (OF), percent depth dose (PDD), and beam profiles in a 6-MV Clinac stereotactic radiosurgery mode for cone irradiation using Monte Carlo simulation as reference. Cones with diameters comprised between 30 and 4 mm have been studied. The evaluated detectors were ionization chambers: pinpoint and pinpoint 3D, diodes: SRS, P and E, Edge, MicroDiamond and EBT3 radiochromic films. The results showed that pinpoints underestimate OF up to −2.3% for cone diameters ≥10 mm and down to −12% for smaller cones. Both nonshielded (SRS and E) and shielded diodes (P and Edge) overestimate the OF respectively up to 3.3% and 5.2% for cone diameters ≥10 mm and in both cases more than 7% for smaller cones. MicroDiamond slightly overestimates the OF, 3.7% for all the cones and EBT3 film is the closest to Monte Carlo with maximum difference of ±1% whatever the cone size is. For the profiles and the PDD, particularly for the small cones, the size of the detector predominates. All diodes and EBT3 agree with the simulation within ±0.2 mm for beam profiles determination. For PDD curve all the active detectors response agree with simulation up to 1% for all the cones. EBT3 is the more accurate detector for beam profiles and OF determinations of stereotactic cones but it is restrictive to use. Due to respectively inappropriate size of the sensitive volume and composition, pinpoints and diodes do not seem appropriate without OF corrective factors below 10 mm diameter cone. MicroDiamond appears to be the best detector for OF determination regardless all cones. For off-axis measurements, the size of the detector predominates and for PDD all detectors give promising results.

References Powered by Scopus

Small fields: Nonequilibrium radiation dosimetry

560Citations
N/AReaders
Get full text

Multichannel film dosimetry with nonuniformity correction

380Citations
N/AReaders
Get full text

A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries-application to far-from-axis fields

227Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams

8Citations
N/AReaders
Get full text

Monte Carlo simulation of conical collimators for stereotactic radiosurgery with a 6 MV flattening-filter-free photon beam

5Citations
N/AReaders
Get full text

SciFi detector and associated method for real-time determination of profile and output factor for small fields in stereotactic radiotherapy

5Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Garnier, N., Amblard, R., Villeneuve, R., Haykal, R., Ortholan, C., Colin, P., … Serrano, B. (2018). Detectors assessment for stereotactic radiosurgery with cones. Journal of Applied Clinical Medical Physics, 19(6), 88–98. https://doi.org/10.1002/acm2.12449

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 9

53%

Researcher 8

47%

Readers' Discipline

Tooltip

Physics and Astronomy 14

64%

Medicine and Dentistry 5

23%

Nursing and Health Professions 2

9%

Philosophy 1

5%

Save time finding and organizing research with Mendeley

Sign up for free