Capnography sensor use is associated with reduction of adverse outcomes during gastrointestinal endoscopic procedures with sedation administration

18Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Evidence to date suggests that capnography monitoring during gastrointestinal endoscopic procedures (GEP) reduces the incidence of hypoxemia, but the association of capnography monitoring with the incidence of other adverse outcomes surrounding these procedures has not been well studied. Our aims were to estimate the incidence of pharmacological rescue events and death at discharge from an inpatient or outpatient hospitalization where GEP was performed with sedation, and to determine if capnography monitoring was associated with reduced incidence of these adverse outcomes. Methods: This retrospective Premier Database analysis included medical inpatients and all outpatients undergoing GEP with sedation. Patients were grouped as follows: (1) pulse oximetry (SpO2) only, (2) capnography only, (3) SpO2 with capnography, and (4) neither SpO2 nor capnography. Multivariable logistic regression and propensity-score matching were used to compare patients with capnography sensor use to patients with only SpO2 sensor use. Outcome measures included the incidence of pharmacological rescue events, as defined by administration of naloxone and/or flumazenil, and death. Results: Two hundred fifty eight thousand and two hundred sixty two inpatients and 3,807,151 outpatients were analyzed. For inpatients, capnography monitoring was associated with a 47% estimated reduction in the odds of death at discharge (OR: 0.53 [95% CI: 0.40-0.70]; P < 0.0001) and a non-significant 10% estimated reduction in the odds of pharmacological rescue event at discharge (0.91 [0.65-1.3]; P = 0.5661). For outpatients, capnography monitoring was associated with a 61% estimated reduction in the odds of pharmacological rescue event at discharge (0.39 [0.29, 0.52]; P < 0.0001) and a non-significant 82% estimated reduction in the odds of death at discharge (0.18 [0.02, 1.99]; P = 0.16). Conclusions: In hospital medical inpatients and all outpatients undergoing GEP performed with sedation, capnography monitoring was associated with a reduced likelihood of pharmacological rescue events in outpatients and death in inpatients when assessed at discharge. Despite the limitations of the retrospective data analysis methodology, the use of capnography during these procedures is recommended.

Cite

CITATION STYLE

APA

Jopling, M. W., & Qiu, J. (2017). Capnography sensor use is associated with reduction of adverse outcomes during gastrointestinal endoscopic procedures with sedation administration. BMC Anesthesiology, 17(1). https://doi.org/10.1186/s12871-017-0453-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free