Intra- and inter-raters reliability and concordance in the evaluation of perineal pressure in nulliparous

1Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

AIMS: To verify intra and inter-rater reliability and concordance in the assessment of perineal pressure in nulliparous women. METHODS: Young, healthy, nulliparous, non-pregnant women who had had sexual intercourse and had a correct contraction of the perineal musculature on physical examination were included. Women were excluded if they used other muscles in a visually perceptible way during the perineal contraction; with changes in the pelvic muscles tone; with urinary incontinence; with cognitive alterations; with disease that could affect the muscular and nervous tissues; or practitioners of high-impact physical activity. The participants were submitted to two assessments of perineal pressure on the same day, with different evaluators. After one week the protocol was repeated. Perineal pressure was determined by means of a perineometer and obtained by the difference between the maximum pressure (Pmax) and the minimum pressure (Pmin) recorded by the device, in millimeters of mercury. Sustained contraction (SC) was evaluated by the time in seconds. In order to determine reliability, the intraclass correlation coefficient (ICC) was used. Bland-Altman test was used for the concordance analysis. Comparison of means was performed by the Wilcoxon test. A value of p≤0.05 was considered significant. RESULTS: Ten participants were included, with a mean age of 23.8±2.9 years and a body mass index of 22.2±1.8 kg/m2. The evaluator A obtained excellent intra-rater reliability for Pmin (ICC=0.86, p<0.01) and Pmax (ICC=0.92, p<0.01); very good reliability for perineal pressure (ICC=0.65, p=0.01); and no statistical significance for SC. For evaluator B, there was no statistical significance for Pmin and Pmax, but there was very good reliability for perineal pressure (ICC=0.78, p<0.01) and SC (ICC=0.70, p<0.01). In the inter-rater analysis (A vs B), on day 1 there was no statistical significance for Pmin, Pmax and perineal pressure; but there was very good reliability for SC (ICC=0.71, p<0.01). On day 2, there was no statistical significance for Pmin and Pmax, but there was very good reliability for perineal pressure (ICC=0.62, p=0.02) and good for SC (ICC=0.56, p=0.03). There was agreement between intra and inter-rater measurements. CONCLUSIONS: Perineal pressure measurements showed very good intra-rater reliability and good to very good inter-rater reliability, with intra and inter-rater concordance.

References Powered by Scopus

STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

42327Citations
N/AReaders
Get full text

Power failure: Why small sample size undermines the reliability of neuroscience

5187Citations
N/AReaders
Get full text

Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM

4109Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Sensory and muscular functions of the pelvic floor in women with endometriosis – cross-sectional study

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Martins, M., Dreher, D. Z., Callegaro, C. C., & Berlezi, E. M. (2019). Intra- and inter-raters reliability and concordance in the evaluation of perineal pressure in nulliparous. Scientia Medica, 29(1). https://doi.org/10.15448/1980-6108.2019.1.32614

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

50%

Professor / Associate Prof. 1

25%

Lecturer / Post doc 1

25%

Readers' Discipline

Tooltip

Medicine and Dentistry 1

100%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 21

Save time finding and organizing research with Mendeley

Sign up for free