In computed tomography, image reconstruction from an insufficient angular range of projection data is called limited angle tomography. Due to missing data, reconstructed images suffer from artifacts, which cause boundary distortion, edge blurring, and intensity biases. Recently, deep learning methods have been applied very successfully to this problem in simulation studies. However, the robustness of neural networks for clinical applications is still a concern. It is reported that most neural networks are vulnerable to adversarial examples. In this paper, we aim to investigate whether some perturbations or noise will mislead a neural network to fail to detect an existing lesion. Our experiments demonstrate that the trained neural network, specifically the U-Net, is sensitive to Poisson noise. While the observed images appear artifact-free, anatomical structures may be located at wrong positions, e.g. the skin shifted by up to 1 cm. This kind of behavior can be reduced by retraining on data with simulated Poisson noise. However, we demonstrate that the retrained U-Net model is still susceptible to adversarial examples. We conclude the paper with suggestions towards robust deep-learning-based reconstruction.
CITATION STYLE
Huang, Y., Würfl, T., Breininger, K., Liu, L., Lauritsch, G., & Maier, A. (2018). Some investigations on robustness of deep learning in limited angle tomography. In Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) (Vol. 11070 LNCS, pp. 145–153). Springer Verlag. https://doi.org/10.1007/978-3-030-00928-1_17
Mendeley helps you to discover research relevant for your work.