Abstract

Purpose: Magnetization transfer saturation ((Formula presented.)) is a useful marker to probe tissue macromolecular content and myelination in the brain. The increased (Formula presented.) -inhomogeneity at (Formula presented.) T and significantly larger saturation pulse flip angles which are often used for postmortem studies exceed the limits where previous (Formula presented.) (Formula presented.) correction methods are applicable. Here, we develop a calibration-based correction model and procedure, and validate and evaluate it in postmortem 7T data of whole chimpanzee brains. Theory: The (Formula presented.) dependence of (Formula presented.) was investigated by varying the off-resonance saturation pulse flip angle. For the range of saturation pulse flip angles applied in typical experiments on postmortem tissue, the dependence was close to linear. A linear model with a single calibration constant (Formula presented.) is proposed to correct bias in (Formula presented.) by mapping it to the reference value of the saturation pulse flip angle. Methods: (Formula presented.) was estimated voxel-wise in five postmortem chimpanzee brains. “Individual-based global parameters” were obtained by calculating the mean (Formula presented.) within individual specimen brains and “group-based global parameters” by calculating the means of the individual-based global parameters across the five brains. Results: The linear calibration model described the data well, though (Formula presented.) was not entirely independent of the underlying tissue and (Formula presented.). Individual-based correction parameters and a group-based global correction parameter ((Formula presented.)) led to visible, quantifiable reductions of (Formula presented.) -biases in high-resolution (Formula presented.) maps. Conclusion: The presented model and calibration approach effectively corrects for (Formula presented.) inhomogeneities in postmortem 7T data.

Cite

CITATION STYLE

APA

Lipp, I., Kirilina, E., Edwards, L. J., Pine, K. J., Jäger, C., Gräßle, T., … Helms, G. (2023). B1+-correction of magnetization transfer saturation maps optimized for 7T postmortem MRI of the brain. Magnetic Resonance in Medicine, 89(4), 1385–1400. https://doi.org/10.1002/mrm.29524

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free