In Vitro Performance Analysis of a Minoxidil Thermosensitive Gel with Reduced Runoff for Eyebrow Hair Growth

0Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

There is a growing interest in innovative products for eyebrow hair loss treatment with fewer adverse effects. Nevertheless, a fundamental formulation aspect of preventing the fragile skin from the ocular region from being irritated is that the formulations remain restricted to the application region and do not run off. Consequently, the methods and protocols in drug delivery scientific research must be adapted to fulfill such performance analysis demand. Thus, this work aimed to propose a novel protocol to evaluate the in vitro performance of a topical gel formulation with a reduced runoff for minoxidil (MXS) delivery to eyebrows. MXS was formulated with 16% poloxamer 407 (PLX) and 0.4% of hydroxypropyl methylcellulose (HPMC). The sol/gel transition temperature, viscosity at 25 °C, and formulation runoff distance on the skin were evaluated to characterize the formulation. The release profile and skin permeation were evaluated in Franz vertical diffusion cells for 12 h and compared to a control formulation (4% PLX and 0.7% HPMC). Then, the formulation’s performance at promoting minoxidil skin penetration with minimum runoff was evaluated in a vertical custom-made permeation template (divided into three areas: superior, middle, and inferior). The MXS release profile from the test formulation was comparable to that from the MXS solution and the control formulation. There was also no difference in the MXS amount that penetrated the skin in the permeation experiments in Franz diffusion cells using the different formulations (p > 0.05). However, the test formulation demonstrated a localized MXS delivery at the application site in the vertical permeation experiment. In conclusion, the proposed protocol could differentiate the test formulation from the control, attesting to its better performance in efficiently delivering MXS to the site of interest (middle third of application). The vertical protocol can be easily employed to evaluate other gels with a drip-free appeal.

Cite

CITATION STYLE

APA

Xavier, L. C. G., Matos, B. N., Barbalho, G. N., Falcão, M. A., Cunha-Filho, M., Gelfuso, G. M., & Gratieri, T. (2023). In Vitro Performance Analysis of a Minoxidil Thermosensitive Gel with Reduced Runoff for Eyebrow Hair Growth. Gels, 9(4). https://doi.org/10.3390/gels9040269

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free