Design and performance evaluation of a laboratory-made 200 nm precut electrical cascade impactor

2Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Increasing public concern regarding air quality has led to the development of efficient aerosol-monitoring techniques. Among the various aerosol measurement instruments based on electrical methods, in this study, an electrical cascade impactor (ECI) was designed and fabricated in our laboratory and was used to measure the real-time size distribution of submicron-sized aerosols. In the study by Park et al. (2007), it was assumed that the size distribution of incoming particles follows a unimodal lognormal distribution. However, in this study, the distribution of particles captured at each stage (including the Faraday cage) was assumed to be a unimodal lognormal distribution; hence, the incoming particles may follow any size distribution. After the particle charging characteristics were obtained for different particle sizes, experiments were performed with monodisperse test particles to determine the collection efficiency of each stage. The current measured in each stage was converted into a number based size distribution of aerosols by using the data inversion algorithm, which utilized the experimentally obtained collection efficiency. Then, a performance evaluation was performed, both in the laboratory and in the field. The results obtained by our ECI were in agreement with the scanning mobility particle sizer (SMPS) data.

References Powered by Scopus

Health effects of fine particulate air pollution: Lines that connect

4546Citations
N/AReaders
Get full text

Ultrafine particulate pollutants induce oxidative stress and mitochondrial damage

1811Citations
N/AReaders
Get full text

The role of oxidative stress in ambient particulate matter-induced lung diseases and its implications in the toxicity of engineered nanoparticles

793Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Inertial impaction technique for the classification of particulate matters and nanoparticles: A review

29Citations
N/AReaders
Get full text

Portable multilateral measurement system employing Optical Particle Counter and one-stage Quartz Crystal Microbalance to measure PM<inf>10</inf>

6Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Han, J., Seo, J., Park, D., Hyun, J., & Hwang, J. (2018). Design and performance evaluation of a laboratory-made 200 nm precut electrical cascade impactor. Aerosol and Air Quality Research, 18(5), 1118–1130. https://doi.org/10.4209/aaqr.2017.11.0471

Readers over time

‘18‘19‘21‘2200.511.52

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

67%

Researcher 1

33%

Readers' Discipline

Tooltip

Engineering 3

75%

Materials Science 1

25%

Save time finding and organizing research with Mendeley

Sign up for free
0