Comparison of ceramic-on-ceramic bearing vs ceramic-on-highly cross-linked polyethylene-bearing surfaces in total hip arthroplasty for avascular necrosis of femoral head: A prospective cohort study with a mid-term follow-up

11Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The ideal bearing surface for patients of avascular necrosis (AVN) undergoing total hip arthroplasty (THA) remains controversial. The purpose of this study is to evaluate the clinical outcomes, health-related quality of life (HRQL), and wear of the bearing surface between ceramic-on-ceramic (CoC) and ceramic-on-highly cross-linked polyethylene (CoXPE) THA for patients of AVN after midterm follow-up. Methods: We performed a retrospective case-control analysis of 93 CoC and 77 CoXPE consecutive THAs for patients of AVN. The cases were followed at a minimum 5 years follow-up (average 7 years). Harris hip score (HHS) score and bearing-related complications were assessed. The health-related quality of life (HRQL) was assessed with the Short Form 36 (SF-36). Plain radiographs and computed tomography (CT) were used for radiographic evaluation. Results: Both the CoC group and CoXPE group showed statistically significant improvements in HHS scores with no difference between the two bearing surfaces. There was no significant difference as for SF-36 at the latest follow-up between two groups, except for significant higher scores in the dimensions of general health in the CoC group (75.7 vs 64.7, P = 0.032). No radiographic evidence of osteolysis and loosening was present at the final follow-up. The mean wear rate of the CoC was 0.0096 mm/year and the CoXPE was 0.047 mm/year after evaluation with reconstructed CT. Conclusions: CoC THAs acts as well as CoXPE THAs for patients with femoral head avascular necrosis after midterm follow-up. CoC bearing can significantly decrease the wearing rate than CoXPE bearing.

References Powered by Scopus

The operation of the century: total hip replacement

2028Citations
N/AReaders
Get full text

Future young patient demand for primary and revision joint replacement: National projections from 2010 to 2030

1225Citations
N/AReaders
Get full text

A literature review of the association between wear rate and osteolysis in total hip arthroplasty

575Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Third-generation ceramic-on-ceramic total hip arthroplasty in patients with osteonecrosis of the femoral head

22Citations
N/AReaders
Get full text

Comprehensive Review on Biomaterials and Their Inherent Behaviors for Hip Repair Applications

15Citations
N/AReaders
Get full text

Future Prospects for Clinical Applications of Nanocarbons Focusing on Carbon Nanotubes

7Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Feng, B., Ren, Y., Cao, S., Lin, J., Jin, J., Qian, W., & Weng, X. (2019). Comparison of ceramic-on-ceramic bearing vs ceramic-on-highly cross-linked polyethylene-bearing surfaces in total hip arthroplasty for avascular necrosis of femoral head: A prospective cohort study with a mid-term follow-up. Journal of Orthopaedic Surgery and Research, 14(1). https://doi.org/10.1186/s13018-019-1410-8

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

60%

Researcher 2

40%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

50%

Nursing and Health Professions 2

17%

Engineering 2

17%

Agricultural and Biological Sciences 2

17%

Save time finding and organizing research with Mendeley

Sign up for free