Accuracy of tympanic temperature measurement in firefighters completing a simulated structural firefighting task

7Citations
Citations of this article
54Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Introduction In the course of their duties, firefighters risk heat stroke and other medical conditions due to exertion in high-temperature environments. Infrared tympanic temperature measurement (TTym) is often used by Emergency Medical Services (EMS) to assess the core body temperature of firefighters. The accuracy of TTym in this setting has been called into question. Hypothesis/Problem This study aimed to examine the accuracy of TTym for core body temperature assessment at emergency firefighting events compared with gastrointestinal temperature measurement (TGI) as measured by ingestible thermometers. Methods Forty-five (42 male, three female) professional urban firefighters from an Australian fire service completed two 20-minute work periods in a 100°C (± 5°C) heat chamber while wearing personal protective clothing (PPC) and breathing apparatus (weighing approximately 22 kg). Measurements were taken immediately before entering, and on exiting, the heat chamber. Tympanic temperature was assessed by an infrared tympanic thermometer and TGI was measured by ingestible sensor and radio receiver. Results Complete data were available for 37 participants. Participant temperatures were higher on exiting the heat chamber than at baseline (TTym: 35.9°C (SD=0.7) vs 37.5°C (SD=0.8); TGI: 37.2°C (SD=0.4) vs 38.6°C (SD=0.5)). Tympanic temperature underestimated TGI on average by 1.3°C (SD=0.5) before entering the chamber and by 1.0°C (SD=0.8) following the exercise. Using pooled data, the average underestimation was 1.2°C (SD=0.7). Conclusion Tympanic thermometers cause an unreliable measure of core body temperature for firefighters engaged in fire suppression activities. Accurate and practical measures of core body temperature are required urgently.

Cite

CITATION STYLE

APA

Keene, T., Brearley, M., Bowen, B., & Walker, A. (2015). Accuracy of tympanic temperature measurement in firefighters completing a simulated structural firefighting task. Prehospital and Disaster Medicine, 30(5), 461–465. https://doi.org/10.1017/S1049023X15005038

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free