Optimum Sample Thickness for Trace Analyte Detection with Field-Resolved Infrared Spectroscopy

15Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The strong absorption of liquid water in the infrared (IR) molecular fingerprint region constitutes a challenge for applications of vibrational spectroscopy in chemistry, biology, and medicine. While high-power IR laser sources enable the penetration of ever thicker aqueous samples, thereby mitigating the detrimental effects of strong attenuation on detection sensitivity, a basic advantage of heterodyne-measurement-based methods has-to the best of our knowledge-not been harnessed in broadband IR measurements to date. Here, employing field-resolved spectroscopy (FRS), we demonstrate in theory and experiment fundamental advantages of techniques whose signal-To-noise ratio (SNR) scales linearly with the electric field over those whose SNR scales linearly with radiation intensity, including conventional Fourier-Transform infrared (FTIR) and direct absorption spectroscopy. Field-scaling brings about two major improvements. First, it squares the measurement dynamic range. Second, we show that the optimum interaction length with samples for SNR-maximized measurements is twice the value usually considered to be optimum for FTIR devices. In order to take full advantage of these properties, the measurement must not be significantly affected by technical noise, such as intensity fluctuations, which are common for high-power sources. Recently, it has been shown that subcycle, nonlinear gating of the molecular fingerprint signal renders FRS robust against intensity noise. Here, we quantitatively demonstrate this advantage of FRS for thick aqueous samples. We report sub-μg/mL detection sensitivities for transmission path lengths up to 80 μm and a limit of detection in the lower μg/mL range for transmission paths as long as 200 μm.

References Powered by Scopus

Terahertz spectroscopy and imaging - Modern techniques and applications

1835Citations
N/AReaders
Get full text

Fourier transform infrared (FTIR) spectroscopy of biological tissues

1410Citations
N/AReaders
Get full text

Free-space electro-optic sampling of terahertz beams

1000Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Mid-infrared cross-comb spectroscopy

19Citations
N/AReaders
Get full text

Ultra-rapid electro-optic sampling of octave-spanning mid-infrared waveforms

19Citations
N/AReaders
Get full text

Compensation of Strong Water Absorption in Infrared Spectroscopy Reveals the Secondary Structure of Proteins in Dilute Solutions

17Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Huber, M., Trubetskov, M., Hussain, S. A., Schweinberger, W., Hofer, C., & Pupeza, I. (2020). Optimum Sample Thickness for Trace Analyte Detection with Field-Resolved Infrared Spectroscopy. Analytical Chemistry, 92(11), 7508–7514. https://doi.org/10.1021/acs.analchem.9b05744

Readers' Seniority

Tooltip

Researcher 10

50%

PhD / Post grad / Masters / Doc 9

45%

Lecturer / Post doc 1

5%

Readers' Discipline

Tooltip

Chemistry 9

50%

Physics and Astronomy 6

33%

Agricultural and Biological Sciences 2

11%

Chemical Engineering 1

6%

Save time finding and organizing research with Mendeley

Sign up for free