Anticoagulation management following left ventricular assist device implantation is similar across all provider strategies†

3Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVES: Thromboembolic and bleeding events are potential complications following left ventricular assist device implantation. A tight control of the international normalized ratio (INR) is believed to be crucial in the reduction of postimplant complications. There is significant variability among institutions as to whether a device implanting centre should be managing the INR. In this study, we evaluated the effect of INR management strategies in maintaining a therapeutic INR. METHODS: A retrospective review was utilized to identify patients implanted with either the HeartMate II or the HeartWare HVAD between January 2011 and February 2016. Patients were stratified into 4 groups based on the post-discharge INR management strategy: outside hospital system anticoagulation clinic, outside hospital primary care provider, implanting centre anticoagulation clinic or implanting centre ventricular assist device office. The INR data were collected and analysed for both the early (discharge, 7, 14, 21 and 30 days) and late (3, 6, 9 and 12 months) postoperative periods. RESULTS: There were 163 patients identified during the study period who met the study inclusion criteria: 49 (30%) patients were managed by an outside hospital system anticoagulation clinic, 59 (36.2%) patients by an outside hospital physician/primary care provider, 22 (13.5%) patients by the implanting centre anticoagulation clinic and 33 (20.2%) patients by the implanting centre ventricular assist device office. There were no statistically significant differences found between management strategies across all time points. CONCLUSIONS: There was no statistically significant difference found between the management strategies examined. Regardless of the chosen INR management strategy, patients have similar INR values and postoperative outcomes.

Cite

CITATION STYLE

APA

McDavid, A., MacBrair, K., Emani, S., Yu, L., Lee, P. H. U., Whitson, B. A., … Kilic, A. (2018). Anticoagulation management following left ventricular assist device implantation is similar across all provider strategies†. Interactive Cardiovascular and Thoracic Surgery, 26(1), 60–65. https://doi.org/10.1093/ICVTS/IVX255

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free