High urinary homoarginine excretion is associated with low rates of all-cause mortality and graft failure in renal transplant recipients

36Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Renal transplant recipients (RTR) have an increased cardiovascular risk profile. Low levels of circulating homoarginine (hArg) are a novel risk factor for mortality and the progression of atherosclerosis. The kidney is known as a major source of hArg, suggesting that urinary excretion of hArg (UhArg) might be associated with mortality and graft failure in RTR. hArg was quantified by mass spectrometry in 24-h urine samples of 704 RTR (functioning graft ≥1 year) and 103 healthy subjects. UhArg determinants were identified with multivariable linear regression models. Associations of UhArg with all-cause mortality and graft failure were assessed using multivariable Cox regression analyses. UhArg excretion was significantly lower in RTR compared to healthy controls [1.62 (1.09-2.61) vs. 2.46 (1.65-4.06) μmol/24 h, P < 0.001]. In multivariable linear regression models, body surface area, diastolic blood pressure, eGFR, pre-emptive transplantation, serum albumin, albuminuria, urinary excretion of urea and uric acid and use of sirolimus were positively associated with UhArg, while donor age and serum phosphate were inversely associated (model R 2 = 0.43). During follow-up for 3.1 (2.7-3.9) years, 83 (12 %) patients died and 45 (7 %) developed graft failure. UhArg was inversely associated with all-cause mortality [hazard risk (HR) 0.52 (95 % CI 0.40-0.66), P < 0.001] and graft failure [HR 0.58 (0.42-0.81), P = 0.001]. These associations remained independent of potential confounders. High UhArg levels are associated with reduced all-cause mortality and graft failure in RTR. Kidney-derived hArg is likely to be of particular importance for proper maintenance of cardiovascular and renal systems.

Cite

CITATION STYLE

APA

Frenay, A. R. S., Kayacelebi, A. A., Beckmann, B., Soedamah-Muhtu, S. S., De Borst, M. H., Van Den Berg, E., … Tsikas, D. (2015). High urinary homoarginine excretion is associated with low rates of all-cause mortality and graft failure in renal transplant recipients. Amino Acids, 47(9), 1827–1836. https://doi.org/10.1007/s00726-015-2038-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free