Diffusion-free valve for preprogrammed immunoassay with capillary microfluidics

8Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

By manipulating the geometry and surface chemistry of microfluidic channels, capillary-driven microfluidics can move and stop fluids spontaneously without external instrumentation. Furthermore, complex microfluidic circuits can be preprogrammed by synchronizing the capillary pressures and encoding the surface tensions of microfluidic chips. A key component of these systems is the capillary valve. However, the main concern for these valves is the presence of unwanted diffusion during the valve loading and activation steps that can cause cross-contamination. In this study, we design and validate a novel diffusion-free capillary valve: the π-valve. This valve consists of a 3D structure and a void area. The void acts as a spacer between two fluids to avoid direct contact. When the valve is triggered, the air trapped within the void is displaced by pneumatic suction induced from the capillary flow downstream without introducing a gas bubble into the circuit. The proposed design eliminates diffusive mixing before valve activation. Numerical simulation is used to study the function and optimize the dimensions of the π-valve, and 3D printing is used to fabricate either the mould or the microfluidic chip. A comparison with a conventional valve (based on a constriction-expansion valve) demonstrates that the π-valve eliminates possible backflow into the valve and reduces the mixing and diffusion during the loading and trigger steps. As a proof-of-concept, this valve is successfully implemented in a capillary-driven circuit for the determination of benzodiazepine, achieving the successive release of 3 solutions in a 3D-printed microfluidic chip without external instrumentation. The results show a 40% increase in the fluorescence intensity using the π-valve relative to the conventional value. Overall, the π-valve prevents cross-contamination, minimizes sample use, and facilitates a sophisticated preprogrammed release of fluids, offering a promising tool for conducting automated immunoassays applicable at point-of-care testing. [Figure not available: see fulltext.]

References Powered by Scopus

The origins and the future of microfluidics

7917Citations
N/AReaders
Get full text

An accurate adaptive solver for surface-tension-driven interfacial flows

1219Citations
N/AReaders
Get full text

Gerris: A tree-based adaptive solver for the incompressible Euler equations in complex geometries

1089Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Rapid prototyping of thermoplastic microfluidic devices via SLA 3D printing

4Citations
N/AReaders
Get full text

Innovations in one-step point-of-care testing within microfluidics and lateral flow assays for shaping the future of healthcare

3Citations
N/AReaders
Get full text

Coupling Capillary-Driven Microfluidics with Lateral Flow Immunoassay for Signal Enhancement

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Azizian, P., Casals-Terré, J., Ricart, J., & Cabot, J. M. (2023). Diffusion-free valve for preprogrammed immunoassay with capillary microfluidics. Microsystems and Nanoengineering, 9(1). https://doi.org/10.1038/s41378-023-00568-2

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

44%

Researcher 3

33%

Professor / Associate Prof. 2

22%

Readers' Discipline

Tooltip

Engineering 7

58%

Chemical Engineering 2

17%

Biochemistry, Genetics and Molecular Bi... 2

17%

Environmental Science 1

8%

Save time finding and organizing research with Mendeley

Sign up for free