Evaluation of initial stress distribution and displacement pattern of craniofacial structures with 3 different rapid maxillary expansion appliance models: A 3-dimensional finite element analysis

2Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: This study aimed to describe the displacement of anatomical structures and the stress distributions caused by the Hyrax, fan-type, and double-hinged expansion screws via the 3-dimensional (3D) finite element method (FEM). Methods: The 3D FEM was based on the computed tomography data of a 12-year-old patient with a constricted maxilla. The Hyrax model included 1,800,981 tetrahedral elements with 2,758,217 nodes. The fan-type model included 1,787,558 tetrahedral elements with 2,737,358 nodes. The double-hinged model included 1,777,080 tetrahedral elements with 2,722,771 nodes. The von Mises stress distributions after 0.2 mm of expansion and displacement patterns after 5 mm of expansion were evaluated. Results: The highest stress accumulation was observed in the sutura zygomatico maxillaris area with all 3 appliances. An increase in stress was noted at the pterygomaxillary fissure, the medial and lateral pterygoid process of the sphenoid bone, and the nasal areas. The wedge-shaped skeletal opening was observed with all 3 appliances. In the transverse plane, maximum posterior expansion was achieved with the Hyrax appliance, whereas the maximum anterior expansion was observed with the double-hinged appliance. The maxilla moved inferiorly and anteriorly with all the 3 appliances. The greatest inferior displacement of the maxilla was recorded with the Hyrax appliance, whereas anterior maxillary displacement was the greatest with the double-hinged appliance. Conclusion: All the appliances showed similar stress distributions. The use of double-hinged screw caused a slight anterior displacement of point A. The fan-type and double-hinged appliances were shown to be more effective on anterior maxillary constriction, whereas the Hyrax appliance might be chosen for resolving maxillary posterior constriction.

References Powered by Scopus

Skeletal and dental changes accompanying rapid midpalatal suture opening

518Citations
N/AReaders
Get full text

Maxillary expansion: Clinical implications

348Citations
N/AReaders
Get full text

Rapid maxillary expansion in the primary and mixed dentitions: A cephalometric evaluation

166Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Evaluation and comparison of stresses and displacements generated by four different types of asymmetric maxillary expansion appliances in true unilateral crossbite using finite element method

2Citations
N/AReaders
Get full text

Evaluation of dental and skeletal effects of the asymmetric rapid maxillary expansion appliance: A three-dimensional finite element study

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Sucu, M., Yilmaz, B., & Ramoğlu, S. İ. (2021). Evaluation of initial stress distribution and displacement pattern of craniofacial structures with 3 different rapid maxillary expansion appliance models: A 3-dimensional finite element analysis. Turkish Journal of Orthodontics, 34(1), 18–25. https://doi.org/10.5152/TURKJORTHOD.2021.20006

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

100%

Readers' Discipline

Tooltip

Medicine and Dentistry 2

50%

Computer Science 1

25%

Social Sciences 1

25%

Save time finding and organizing research with Mendeley

Sign up for free