Accuracy of deep learning-based computed tomography diagnostic system for COVID-19: A consecutive sampling external validation cohort study

3Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Ali-M3, an artificial intelligence program, analyzes chest computed tomography (CT) and detects the likelihood of coronavirus disease (COVID-19) based on scores ranging from 0 to 1. However, Ali-M3 has not been externally validated. Our aim was to evaluate the accuracy of Ali-M3 for detecting COVID-19 and discuss its clinical value. We evaluated the external validity of Ali-M3 using sequential Japanese sampling data. In this retrospective cohort study, COVID-19 infection probabilities for 617 symptomatic patients were determined using Ali-M3. In 11 Japanese tertiary care facilities, these patients underwent reverse transcription-polymerase chain reaction (RT-PCR) testing. They also underwent chest CT to confirm a diagnosis of COVID-19. Of the 617 patients, 289 (46.8%) were RT-PCR-positive. The area under the curve (AUC) of Ali-M3 for predicting a COVID-19 diagnosis was 0.797 (95% confidence interval: 0.762–0.833) and the goodness-of-fit was P = 0.156. With a cutoff probability of a diagnosis of COVID-19 by Ali-M3 set at 0.5, the sensitivity and specificity were 80.6% and 68.3%, respectively. A cut-off of 0.2 yielded a sensitivity and specificity of 89.2% and 43.2%, respectively. Among the 223 patients who required oxygen, the AUC was 0.825. Sensitivity at a cut-off of 0.5% and 0.2% was 88.7% and 97.9%, respectively. Although the sensitivity was lower when the days from symptom onset were fewer, the sensitivity increased for both cut-off values after 5 days. We evaluated Ali-M3 using external validation with symptomatic patient data from Japanese tertiary care facilities. As Ali-M3 showed sufficient sensitivity performance, despite a lower specificity performance, Ali-M3 could be useful in excluding a diagnosis of COVID-19.

Cite

CITATION STYLE

APA

Ikenoue, T., Kataoka, Y., Matsuoka, Y., Matsumoto, J., Kumasawa, J., Tochitatni, K., … Fukuma, S. (2021). Accuracy of deep learning-based computed tomography diagnostic system for COVID-19: A consecutive sampling external validation cohort study. PLoS ONE, 16(11 November). https://doi.org/10.1371/journal.pone.0258760

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free