This paper presents a prototype test fixture for the absolute calibration and estimation of the equivalent magnetic flux noise of the extremely low frequency (ELF) Schumann resonant (SR) magnetic antenna receiver and rods’ magnetic permeability measurement. The test fixture, for ELF the SR detector’s calibration, consists of a constructed coil, the signal generator, and the oscilloscope. The ELF SR detector used has been operating since 2016 near the Doliana village in the Ioannina prefecture, Northwestern Greece. At precisely this spot, far away from electromagnetic noise, the whole setup and experiment took place. The experiments performed with the proposed test fixture showed a sensitivity of 70 nV/pT/Hz and an apparent magnetic permeability at around 250 for the magnetic antenna. The total sensitivity of the ELF receiver was 210 mV/pT near 20 Hz, while the total input noise was around 0.04 pT.

Cite

CITATION STYLE

APA

Tatsis, G., Christofilakis, V., Chronopoulos, S. K., Kostarakis, P., Nistazakis, H. E., Repapis, C., & Tritakis, V. (2020). Design and implementation of a test fixture for ELF schumann resonance magnetic antenna receiver and magnetic permeability measurements. Electronics (Switzerland), 9(1). https://doi.org/10.3390/electronics9010171