Endosonography-guided drainage of pancreatic fluid collections with a novel lumen-apposing stent

120Citations
Citations of this article
41Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: The purpose of this study is to report our initial experience with a new fully covered metallic stent with a novel design (AXIOS) to prevent migration and fluid leakage, in the drainage of pancreatic fluid collections (PFC). Methods: We included nine patients from four Spanish centers undergoing endoscopic ultrasound (EUS)-guided drainage of PFC with placement of an AXIOS stent. The lesions were accessed via transgastric (n = 7), transesophageal (n = 1), and transduodenal (n = 1) by using a novel access device (NAVIX) in six cases or a 19-G needle in three. Patients were individually followed prospectively for procedure indications, demographic data, previous imaging techniques, technical aspects, clinical outcomes, complications, and follow-up after endoscopic drainage. Results: The mean size of lesions was 105 ± 26.3 mm (range, 70-150). In six cases, cystoscopy was performed through the stent, including necrosectomy in two. Median procedure time was 25 ± 13 min. A median number of two sessions were performed. The technical success rate was 88.8 % (8/9) due to one failure of the delivery system. One patient developed a tension pneumothorax immediately after transesophageal drainage. No migrations were reported, and all stents were removed easily. All patients had a successful treatment outcome achieving complete cyst resolution. Mean time to stent retrieval was 33 ± 40 days. Mean follow-up was 50 ± 1.3 weeks (range, 45-55), and only one patient presented a recurrence 4 weeks after the stent removal. Furthermore, comparison with ten previous consecutively recruited PFC cases drained by EUS-guided using plastic pigtail stents was done. Technical and clinical successes were similar. However, two stent migrations, two recurrences, and two complications were found. The number of stents used (n = 15) and the median procedure time (42.8 ± 3.1 min) were significantly higher. Conclusions: Drainage of PFC using dedicated devices as this novel metallic stent with special design seems to be an effective, feasible and safe alternative technique. © 2012 Springer Science+Business Media New York.

Cite

CITATION STYLE

APA

Gornals, J. B., De La Serna-Higuera, C., Sánchez-Yague, A., Loras, C., Sánchez-Cantos, A. M., & Pérez-Miranda, M. (2013). Endosonography-guided drainage of pancreatic fluid collections with a novel lumen-apposing stent. Surgical Endoscopy, 27(4), 1428–1434. https://doi.org/10.1007/s00464-012-2591-y

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free