Common carotid segmentation in 18F-sodium fluoride PET/CT scans: Head-to-head comparison of artificial intelligence-based and manual method

2Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Carotid atherosclerosis is a major cause of stroke, traditionally diagnosed late. Positron emission tomography/computed tomography (PET/CT) with 18F-sodium fluoride (NaF) detects arterial wall micro-calcification long before macro-calcification becomes detectable by ultrasound, CT or magnetic resonance imaging. However, manual PET/CT processing is time-consuming and requires experience. We compared a convolutional neural network (CNN) approach with manual segmentation of the common carotids. Methods: Segmentation in NaF-PET/CT scans of 29 healthy volunteers and 20 angina pectoris patients were compared for segmented volume (Vol) and mean, maximal, and total standardized uptake values (SUVmean, SUVmax, and SUVtotal). SUVmean was the average of SUVmeans within the VOI, SUVmax the highest SUV in all voxels in the VOI, and SUVtotal the SUVmean multiplied by the Vol of the VOI. Intra and Interobserver variability with manual segmentation was examined in 25 randomly selected scans. Results: Bias for Vol, SUVmean, SUVmax, and SUVtotal were 1.33 ± 2.06, −0.01 ± 0.05, 0.09 ± 0.48, and 1.18 ± 1.99 in the left and 1.89 ± 1.5, −0.07 ± 0.12, 0.05 ± 0.47, and 1.61 ± 1.47, respectively, in the right common carotid artery. Manual segmentation lasted typically 20 min versus 1 min with the CNN-based approach. Mean Vol deviation at repeat manual segmentation was 14% and 27% in left and right common carotids. Conclusions: CNN-based segmentation was much faster and provided SUVmean values virtually identical to manually obtained ones, suggesting CNN-based analysis as a promising substitute of slow and cumbersome manual processing.

Cite

CITATION STYLE

APA

Piri, R., Hamakan, Y., Vang, A., Edenbrandt, L., Larsson, M., Enqvist, O., … Høilund-Carlsen, P. F. (2023). Common carotid segmentation in 18F-sodium fluoride PET/CT scans: Head-to-head comparison of artificial intelligence-based and manual method. Clinical Physiology and Functional Imaging, 43(2), 71–77. https://doi.org/10.1111/cpf.12793

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley