Axial alignment is one of the main objectives in total knee arthroplasty (TKA). Computer-assisted surgery (CAS) is more accurate regarding limb alignment reconstruction compared to the conventional technique. The aim of this study was to analyse the precision of the innovative navigation system DASH® by Brainlab and to evaluate the reliability of intraoperatively acquired data. A retrospective analysis of 40 patients was performed, who underwent CAS TKA using the iPod-based navigation system DASH. Pre- and postoperative axial alignment were measured on standardized radiographs by two independent observers. These data were compared with the navigation data. Furthermore, interobserver reliability was measured. The duration of surgery was monitored. The mean difference between the preoperative mechanical axis by X-ray and the first intraoperatively measured limb axis by the navigation system was 2.4°. The postoperative X-rays showed a mean difference of 1.3° compared to the final navigation measurement. According to radiographic measurements, 88% of arthroplasties had a postoperative limb axis within ±3°. The mean additional time needed for navigation was 5 minutes. We could prove very good precision for the DASH system, which is comparable to established navigation devices with only negligible expenditure of time compared to conventional TKA.

References Powered by Scopus

The measurement of observer agreement for categorical data

60920Citations
N/AReaders
Get full text

Why are total knee arthroplasties failing today?

1184Citations
N/AReaders
Get full text

The epidemiology of revision total knee arthroplasty in the united states

1065Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Total knee arthroplasties from the origin to navigation: history, rationale, indications

20Citations
N/AReaders
Get full text

Femoral flexion position is a highly variable factor in total knee arthroplasty: an analysis of 593 conventionally aligned total knee replacements

12Citations
N/AReaders
Get full text

Current concepts and future perspectives in computer-assisted navigated total knee replacement

12Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Koenen, P., Schneider, M. M., Fröhlich, M., Driessen, A., Bouillon, B., & Bäthis, H. (2016). Reliable Alignment in Total Knee Arthroplasty by the Use of an iPod-Based Navigation System. Advances in Orthopedics, 2016. https://doi.org/10.1155/2016/2606453

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

60%

Researcher 3

30%

Professor / Associate Prof. 1

10%

Readers' Discipline

Tooltip

Medicine and Dentistry 8

67%

Engineering 2

17%

Nursing and Health Professions 1

8%

Arts and Humanities 1

8%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 2

Save time finding and organizing research with Mendeley

Sign up for free