Abstract

Simulations of emergency states and tests of resistance of electrical devices to emergencies are performed in specialized high‐power laboratories, the so‐called short‐circuit laboratories. For most electrical power devices, such measurements are required by international standards. The basic equipment of short‐circuit testing laboratories consists of current transformers for measuring short‐circuit currents. These transformers should not only enable the accurate conversion of sinusoidal currents—which is typical for conventional current transformers, but also asymmetrical short-circuit currents containing an aperiodic component, which classic current transformers cannot re-produce. Therefore, manufacturers and designers try to meet the market demands and design these special class 0.2 current transformers. To meet the high technical requirements, the field‐circuit method with three‐dimensional space–time analysis of electromagnetic fields was used during de-sign, considering physical phenomena in ferromagnetic cores (i.e., hysteresis and eddy current losses) and the load of the secondary winding of the current transformer by the measurement sys-tem. The article presents simulations of secondary currents for the short‐circuit current transformer model, and the results were confirmed by measurements and oscillograms of the currents flowing in the windings of the real model. The prototype of the designed short‐circuit transformer meets the IEC/EN standard requirements. When measuring harmonic currents, the transformation errors meet the requirements of class 0.2. During the short‐circuit current waveforms, the maximum in-stantaneous peak error does not exceed 1% of the error for all the subsequent maxima of the current waveform during the specified transient switching cycle. In comparison, the standard allows this error to be 10%.

Cite

CITATION STYLE

APA

Lesniewska, E., & Olak, J. (2022). Analysis of the Operation of Cascade Current Transformers for Measurements of Short‐Circuit Currents with a Non‐Periodic Component with a Large Time Constant of Its Decay. Energies, 15(8). https://doi.org/10.3390/en15082925

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free