Evaluation of a new interrupter device for measuring bronchial responsiveness and the response to bronchodilator in 3-year-old children

81Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

Abstract

The interrupter technique for measuring airway resistance is noninvasive and convenient, and therefore ideally suited for the assessment of induced changes in airway calibre in preschool children. The aim of this study was to evaluate a commercially available interrupter device (based on Microlab 4000), which calculates the interrupter resistance (Rint) from pressure and flow following a brief interruption of expiration during quiet breathing. The repeatability of Rint was assessed, and its response to methacholine challenge and the bronchodilator salbutamol were compared with an indirect technique, the fall in transcutaneous oxygen tension (Ptc,O2), using the sensitivity index (SI, i.e. the change after challenge expressed in multiples of the baseline standard deviation) in 12 wheezy children (aged 3 yrs ± 2 months). The mean (SD) baseline value of Rint was 0.91 (0.20) kPa·L-1·s. Short-term repeatability and baseline variability were satisfactory for Rint (intraclass correlation coefficient = 0.6; mean intrasubject coefficient of variation = 13%). Although 10 of the 12 subjects obtained a significant response using Rint at maximal bronchoconstriction (i.e. SI > 2), overall, Rint was five times less sensitive than Ptc,O2 (geometric mean SI: Rint 3 vs Ptc,O2 16; p < 0.0001). Reversal of obstruction with administration of a bronchodilator was clearly demonstrated in almost all subjects: Rint after challenge (mean ± SD) 1.25 (0.22) kPa·L-1·s; after salbutamol 0.78 (0.19) kPa·L-1·s; p < 0.001. In conclusion, the convenient interrupter resistance method appears more promising for detecting bronchodilator responses than induced bronchoconstriction in wheezy preschool children; however, measurement of transcutaneous oxygen tension provides a reliable indirect means of detecting induced airway obstruction in this age-group.

References Powered by Scopus

Repeatability and method comparison

324Citations
N/AReaders
Get full text

A theoretical analysis of interrupter technique for measuring respiratory mechanics

185Citations
N/AReaders
Get full text

The measurement of methacholine responsiveness in 5 year old children: Three methods compared

94Citations
N/AReaders
Get full text

Cited by Powered by Scopus

An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary function testing in preschool children

1018Citations
N/AReaders
Get full text

Specific airway resistance in 3-year-old children: A prospective cohort study

140Citations
N/AReaders
Get full text

Interrupter resistance in preschool children: Measurement characteristics and reference values

106Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Phagoo, S. B., Wilson, N. M., & Silverman, M. (1996). Evaluation of a new interrupter device for measuring bronchial responsiveness and the response to bronchodilator in 3-year-old children. European Respiratory Journal, 9(7), 1374–1380. https://doi.org/10.1183/09031936.96.09071374

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

42%

Professor / Associate Prof. 4

33%

Researcher 2

17%

Lecturer / Post doc 1

8%

Readers' Discipline

Tooltip

Medicine and Dentistry 12

86%

Agricultural and Biological Sciences 1

7%

Social Sciences 1

7%

Save time finding and organizing research with Mendeley

Sign up for free