Quantitative measurements of backside wear in acetabular hip joint replacement: Conventional polyethylene versus cross-linked polyethylene

4Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

As shown in previous studies, the modification of conventional polyethylene (CPE) to cross-linked polyethylene (XLPE) and the contribution of antioxidants result in a reduction in total wear. The aim of this study was to evaluate XLPE inserts with vitamin E and CPE regarding their resistance to the backside wear mechanism. A cementless hip cup system (Plasmafit® Plus 7, Aesculap) was dynamically loaded using CPE and XLPE inserts. The backside wear was isolated, generated and collected using the two-chamber principle. The chambers were filled with ultrapure water. After 2 x 106 cycles, the fluids were examined for wear particles according to a particle analysis. Using XLPE inserts, the backside wear was significantly reduced by 35%. While XLPE backside wear particles are significantly larger than CPE particles, they do not differ in their morphology. This study confirms the greater resistance to backside wear of XLPE compared to CPE. It can be assumed that the improved fatigue resistance of the vitamin E-stabilized XLPE inserts demonstrates XLPE's effectiveness against micro-motion and the resulting changing tensions in interface areas like surface breakdown, pitting and the release of very small particles.

References Powered by Scopus

Wear Resistance and Mechanical Properties of Highly Cross-linked, Ultrahigh-Molecular Weight Polyethylene Doped With Vitamin E

287Citations
N/AReaders
Get full text

Vitamin E diffused, highly crosslinked UHMWPE: A review

207Citations
N/AReaders
Get full text

The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles

164Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Mixed material wear particle isolation from periprosthetic tissue surrounding total joint replacements

11Citations
N/AReaders
Get full text

Future Prospects for Clinical Applications of Nanocarbons Focusing on Carbon Nanotubes

7Citations
N/AReaders
Get full text

Tribology in arthroplasty: Friction and wear, a key to a long lifetime

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Braun, S., Jaeger, S., Sonntag, R., Schroeder, S., & Kretzer, J. P. (2020). Quantitative measurements of backside wear in acetabular hip joint replacement: Conventional polyethylene versus cross-linked polyethylene. Materials, 13(8). https://doi.org/10.3390/MA13081854

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

75%

Researcher 1

25%

Readers' Discipline

Tooltip

Medicine and Dentistry 2

40%

Design 1

20%

Energy 1

20%

Engineering 1

20%

Save time finding and organizing research with Mendeley

Sign up for free