Study Protocol. IDUS - Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery

8Citations
Citations of this article
58Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Instrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 - 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice.Methods/Design: A multi-centre randomised controlled trial is proposed. The study will take place in two large maternity units in Ireland with a combined annual birth rate of 13,500 deliveries. It will involve 450 nulliparous women undergoing instrumental delivery after 37 weeks gestation. The main outcome measure will be incorrect diagnosis of the fetal head position. A study involving 450 women will have 80% power to detect a 10% difference in the incidence of inaccurate diagnosis of the fetal head position with two-sided 5% alpha.Discussion: It is both important and timely to evaluate the use of ultrasound to diagnose the fetal head position prior to instrumental delivery before routine use can be advocated. The overall aim is to reduce the incidence of incorrect diagnosis of the fetal head position prior to instrumental delivery and improve the safety of instrumental deliveries.Trial registration: Current Controlled Trials ISRCTN72230496. © 2012 Murphy et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Murphy, D. J., Burke, G., Montgomery, A. A., & Ramphul, M. (2012). Study Protocol. IDUS - Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery. BMC Pregnancy and Childbirth, 12. https://doi.org/10.1186/1471-2393-12-95

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free