In vivo performance of an acellular disc-like angle ply structure (DAPS) for total disc replacement in a small animal model

25Citations
Citations of this article
47Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Total intervertebral disc replacement with a biologic engineered disc may be an alternative to spinal fusion for treating end-stage disc disease. In previous work, we developed disc-like angle ply structures (DAPS) that replicate the structure and function of the native disc and a rat tail model to evaluate DAPS in vivo. Here, we evaluated a strategy in which, after in vivo implantation, endogenous cells could colonize the acellular DAPS and form an extracellular matrix organized by the DAPS topographical template. To do so, acellular DAPS were implanted into the caudal spines of rats and evaluated over 12 weeks by mechanical testing, histology, and microcomputed tomography. An external fixation device was used to stabilize the implant site and various control groups were included to evaluate the effect of immobilization. There was robust tissue formation within the DAPS after implantation and compressive mechanical properties of the implant matched that of the native motion segment. Immobilization provided a stable site for fibrous tissue formation after either a discectomy or a DAPS implantation, but bony fusion eventually resulted, with segments showing intervertebral bridging after long-term implantation, a process that was accelerated by the implanted DAPS. Thus, while compressive mechanical properties were replicated after DAPS implantation, methods to actively prevent fusion must be developed. Future work will focus on limiting fusion by remobilizing the motion segment after a period of integration, delivering pro-chondrogenic factors, and pre-seeding DAPS with cells prior to implantation. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:23–31, 2017.

Cite

CITATION STYLE

APA

Martin, J. T., Kim, D. H., Milby, A. H., Pfeifer, C. G., Smith, L. J., Elliott, D. M., … Mauck, R. L. (2017). In vivo performance of an acellular disc-like angle ply structure (DAPS) for total disc replacement in a small animal model. Journal of Orthopaedic Research, 35(1), 23–31. https://doi.org/10.1002/jor.23310

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free