COVID-19 Rapid Antigen Tests with Self-Collected vs Health Care Worker-Collected Nasal and Throat Swab Specimens: A Randomized Clinical Trial

9Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Importance: Self- or health care worker (HCW)-collected nasal swab specimens are the preferred sampling method to perform rapid antigen testing for COVID-19, but it is debated whether throat specimens can improve test sensitivity. Objective: To compare the diagnostic accuracy of self- and HCW-collected nasal vs throat swab specimens for COVID-19 rapid antigen testing. Design, Setting, and Participants: This per-protocol multicenter randomized clinical trial was conducted from February 15 through March 25, 2022. The participants, individuals aged 16 years or older requesting a COVID-19 test for diagnostic or screening purposes, had 4 specimens collected for individual testing at 1 of 2 urban COVID-19 outpatient test centers in Copenhagen, Denmark. Interventions: Participants were randomized 1:1 to self-collected or HCW-collected nasal and throat swab specimens for rapid antigen testing. Additional HCW-collected nasal and throat swab specimens for reverse transcriptase-polymerase chain reaction (RT-PCR) were used as the reference standard. Main Outcomes and Measures: The primary outcome was sensitivity to diagnose COVID-19 of a self- vs HCW-collected nasal and throat specimen for rapid antigen testing compared with RT-PCR. Results: Of 2941 participants enrolled, 2674 (90.9%) had complete test results and were included in the final analysis (1535 [57.4%] women; median age, 40 years [IQR, 28-55 years]); 1074 (40.2%) had COVID-19 symptoms, and 827 (30.9%) were positive for SARS-CoV-2 by RT-PCR. Health care worker-collected throat specimens had higher mean sensitivity than HCW-collected nasal specimens for rapid antigen testing (69.4% [95% CI, 65.1%-73.6%] vs 60.0% [95% CI, 55.4%-64.5%]). However, a subgroup analysis of symptomatic participants found that self-collected nasal specimens were more sensitive than self-collected throat specimens for rapid antigen testing (mean sensitivity, 71.5% [95% CI, 65.3%-77.6%] vs 58.0% [95% CI, 51.2%-64.7%]; P

Cite

CITATION STYLE

APA

Todsen, T., Jakobsen, K. K., Grønlund, M. P., Callesen, R. E., Folke, F., Larsen, H., … Von Buchwald, C. (2023). COVID-19 Rapid Antigen Tests with Self-Collected vs Health Care Worker-Collected Nasal and Throat Swab Specimens: A Randomized Clinical Trial. JAMA Network Open, 6(12), E2344295. https://doi.org/10.1001/jamanetworkopen.2023.44295

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free