Clinical validation of time reduction strategy in continuous step-and-shoot mode during SPECT acquisition

17Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The SwiftScan solution (General Electric Healthcare) combines a new low-energy high-resolution sensitivity collimator and a tomographic step-and-shoot continuous (SSC) mode acquisition. The purpose of this study is to determine whether SSC mode can be used in clinical practice with shorter examination times, while preserving image quality and ensuring accurate semi-quantification. Twenty bone scan and 10 lung scan studies were randomly selected over a period of 2 months. Three sets of image datasets were produced: step-and-shoot (SS) acquisition, simulated 25% count reduction using the Poisson resampling method (SimSS), and SimSS continuous acquisition (SimSSC), where SimSS was summed with counts acquired during detector head rotation. Visual assessment (5-point Likert scale, 2 readers) and semi-quantitative evaluation (50 focal uptake from 10 bone studies), assessed by SUVmean, coefficient of variation (COV), and contrast-to-noise ratio (CNR), were performed using t test and Bland-Altman analysis. Results: Intra-reader agreement was substantial for reader 1 (k = 0.71) and for reader 2 (k = 0.61). Inter-reader agreement was substantial for SS set (k = 0.93) and moderate for SimSSC (k = 0.52). Bland-Altman analysis showed a good interchangeability of SS and SimSSC SUV values. The mean CNR between SS and SimSSC was not significantly different: 42.9 ± 43.7 [23.7–62.1] vs. 43.1 ± 46 [22.9–63.3] (p = 0.46), respectively. COV values, assessing noise level, did not deviate significantly between SS and SimSSC: 0.20 ± 0.08 [0.18–0.23] vs. 0.21 ± 0.08, [0.18–0.23] (p = 0.15), respectively, whereas a significant difference was demonstrated between SS and SimSS: 0.20 ± 0.08 [0.18–0.23] vs. 0.23 ± 0.09 [0.20–0.25] (p < 0.0001), respectively. Conclusions: SSC mode acquisition decreases examination time by approximately 25% in bone and lung SPECT/CT studies compared to SS mode (~ 2 min per single-bed SPECT), without compromising image quality and signal quantification. This SPECT sensitivity improvement also offers the prospect of more comfortable exams, with less motion artifacts, especially in painful or dyspneic patients.

References Powered by Scopus

An application of hierarchical Kappa type statistics in the assessment of majority agreement among multiple observers

3020Citations
N/AReaders
Get full text

Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: First clinical validation

159Citations
N/AReaders
Get full text

Scoring systems used for the interpretation and reporting of multiparametric MRI for prostate cancer detection, localization, and characterization: Could standardization lead to improved utilization of imaging within the diagnostic pathway?

129Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Recent Developments in SPECT/CT

55Citations
N/AReaders
Get full text

PET/CT and SPECT/CT for Infection in Joints and Bones: An Overview and Future Directions

8Citations
N/AReaders
Get full text

Deep learning enhanced ultra-fast SPECT/CT bone scan in patients with suspected malignancy: quantitative assessment and clinical performance

7Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Picone, V., Makris, N., Boutevin, F., Roy, S., Playe, M., & Soussan, M. (2021). Clinical validation of time reduction strategy in continuous step-and-shoot mode during SPECT acquisition. EJNMMI Physics, 8(1). https://doi.org/10.1186/s40658-021-00354-x

Readers over time

‘21‘22‘23‘2405101520

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

50%

Researcher 6

43%

Professor / Associate Prof. 1

7%

Readers' Discipline

Tooltip

Medicine and Dentistry 9

64%

Nursing and Health Professions 3

21%

Pharmacology, Toxicology and Pharmaceut... 1

7%

Computer Science 1

7%

Save time finding and organizing research with Mendeley

Sign up for free
0