In the present study, we developed a liquid chromatography-diode array detector-electrospray ionization/mass spectrometric (LC-DAD-ESI/MS) method for analysis of saikosaponins in Bupleurum falcatum. The LC method employed a ZORBAX SB-Aq analytical column (150 × 4.6 mm i.d., 5 μm) at a flow rate of 0.8 mL/min coupled with a diode array detector at 204 nm. A step gradient of acetonitrile-water (v/v) containing 0.5% formic acid from 30 to 70% was applied, leading to a sample analysis time of 30 min. The ESI-MS was carried out in positive and negative modes from 500 to 1,500 m/z. Saikosaponins c, a, and d gave strong sodium adducts at m/z 949.6, 803.5 and 803.6, respectively, in positive mode. The data indicate that the present LC-DAD-ESI/MS assay is an effective method for the determination of saikosaponins c, a and d from the roots of Bupleurum falcatum. © 2011.
CITATION STYLE
Zhao, L. C., Li, W., He, Y. F., Li, X. H., Wang, Z., Liu, W. C., … Liang, J. (2011). Fast and sensitive LC-DAD-ESI/MS method for analysis of saikosaponins c, a, and d from the roots of bupleurum falcatum (Sandaochaihu). Molecules, 16(2), 1533–1543. https://doi.org/10.3390/molecules16021533