Automatic configuration of the reference point method for fully automated multi-objective treatment planning applied to oropharyngeal cancer

3Citations
Citations of this article
26Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: In automated treatment planning, configuration of the underlying algorithm to generate high-quality plans for all patients of a particular tumor type can be a major challenge. Often, a time-consuming trial-and-error tuning procedure is required. The purpose of this paper is to automatically configure an automated treatment planning algorithm for oropharyngeal cancer patients. Methods: Recently, we proposed a new procedure to automatically configure the reference point method (RPM), a fast automatic multi-objective treatment planning algorithm. With a well-tuned configuration, the RPM generates a single Pareto optimal treatment plan with clinically favorable trade-offs for each patient. The automatic configuration of the RPM requires a set of computed tomography (CT) scans with corresponding dose distributions for training. Previously, we demonstrated for prostate cancer planning with 12 objectives that training with only 9 patients resulted in high-quality configurations. This paper further develops and explores the new automatic RPM configuration procedure for head and neck cancer planning with 22 objectives. Investigations were performed with planning CT scans of 105 previously treated unilateral or bilateral oropharyngeal cancer patients together with corresponding Pareto optimal treatment plans. These plans were generated with our clinically applied two-phase ε-constraint method (Erasmus-iCycle) for automated multi-objective treatment planning, ensuring consistent high quality and Pareto optimality of all plans. Clinically relevant, nonconvex criteria, such as dose-volume parameters and NTCPs, were included to steer the RPM configuration. Results: Training sets with 20–50 patients were investigated. Even with 20 training plans, high-quality configurations of the RPM were feasible. Automated plan generation with the automatically configured RPM resulted in Pareto optimal plans with overall similar or better quality than that of the Pareto optimal database plans. Conclusions: Automatic configuration of the RPM for automated treatment planning is feasible and drastically reduces the time and workload required when compared to manual tuning of an automated treatment planning algorithm.

References Powered by Scopus

Reporting and analyzing dose distributions: A concept of equivalent uniform dose

991Citations
N/AReaders
Get full text

Complication probability as assessed from dose-volume histograms.

409Citations
N/AReaders
Get full text

On the completeness and constructiveness of parametric characterizations to vector optimization problems

326Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Dose prediction with deep learning for prostate cancer radiation therapy: Model adaptation to different treatment planning practices

63Citations
N/AReaders
Get full text

Artificial Intelligence in Radiation Therapy

17Citations
N/AReaders
Get full text

IDOL: A web application for mixed integer linear multiobjective optimization

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

van Haveren, R., Heijmen, B. J. M., & Breedveld, S. (2020). Automatic configuration of the reference point method for fully automated multi-objective treatment planning applied to oropharyngeal cancer. Medical Physics, 47(4), 1499–1508. https://doi.org/10.1002/mp.14073

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

75%

Professor / Associate Prof. 1

13%

Lecturer / Post doc 1

13%

Readers' Discipline

Tooltip

Physics and Astronomy 4

50%

Engineering 2

25%

Computer Science 1

13%

Nursing and Health Professions 1

13%

Save time finding and organizing research with Mendeley

Sign up for free