Diurnal intraocular pressure fluctuation and its risk factors in angle-closure and open-angle glaucoma

22Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

Abstract

Purpose: To evaluate intraocular pressure (IOP) fluctuation during office hours and its predictive factors in untreated primary angle-closure suspects (PACS); post-iridotomy primary angle closure (PAC) and primary angle-closure glaucoma (PACG) eyes with or without IOP-lowering medication(s) as appropriate and medically treated primary open-angle glaucoma (POAG) eyes. Methods: One-hundred seventeen eyes (29 PACS, 30 PAC, 28 PACG, and 30 POAG) of 117 patients were included in this cross-sectional study. The subjects underwent hourly IOP measurements with Goldmann tonometer from 0800 to 1700 hours. Subjects with PAC and PACG had laser peripheral iridotomy at least 2 weeks prior to the inclusion. SD of office-hour IOP readings was the main outcome measure. Results: IOP fluctuation differed between the groups (P=0.01; Kruskal-Wallis Test). Post hoc Mann-Whitney U-tests showed significantly less IOP fluctuation in PACS compared with PACG (P<0.01). Peak office-hour IOP was observed in the morning in untreated subjects and in the early afternoon in treated subjects. A stepwise linear regression model identified the presence of peripheral anterior synechiae (PAS), thickness of lens, large vertical cup-to-disc ratio (VCDR), and PAC category as significant predictive factors associated with office-hour IOP fluctuation. Conclusions: Diurnal IOP fluctuation in asymptomatic PACSs was less than that in treated PACG subjects and was at least comparable to that in treated PAC and POAG subjects. The greater the amount of PAS, the thicker the lens, the larger the VCDR, the greater was the IOP fluctuation during office hours.

References Powered by Scopus

The definition and classification of glaucoma in prevalence surveys

1953Citations
N/AReaders
Get full text

Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma

809Citations
N/AReaders
Get full text

Diurnal variations in axial length, choroidal thickness, intraocular pressure, and ocular biometrics

403Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Optic Disc and Macular Vessel Density Measured by Optical Coherence Tomography Angiography in Open-Angle and Angle-Closure Glaucoma

28Citations
N/AReaders
Get full text

Corneoscleral stiffening increases IOP spike magnitudes during rapid microvolumetric change in the eye

25Citations
N/AReaders
Get full text

Seasonal fluctuation in intraocular pressure and its associated factors in primary open-angle glaucoma

21Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Srinivasan, S., Choudhari, N. S., Baskaran, M., George, R. J., Shantha, B., & Vijaya, L. (2016). Diurnal intraocular pressure fluctuation and its risk factors in angle-closure and open-angle glaucoma. Eye (Basingstoke), 30(3), 362–368. https://doi.org/10.1038/eye.2015.231

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 12

71%

Professor / Associate Prof. 3

18%

Researcher 2

12%

Readers' Discipline

Tooltip

Medicine and Dentistry 10

67%

Engineering 2

13%

Agricultural and Biological Sciences 2

13%

Nursing and Health Professions 1

7%

Save time finding and organizing research with Mendeley

Sign up for free